00194798-01 - 第16页
Installation Manual, Station Software Version 602.01 Edition 06/2006 3.4 Network configuration Station computer Machine c ontroller 10Base-T 100Base -T Private network betw een station computer and machine control ler SI…

Installation Manual, Station Software Version 602.01 Edition 06/2006
15 of 60
3.3.1 Station computer
Name SIMATIC Box PC 627
CPU / clock frequency Pentium M / 2 GHz
RAM 1 GB
Hard disk 40 GB
CD ROM drive Yes
Serial interfaces 1
Network 2x 100 MBit
Table 3-4: Station computer hardware (SIPLACE D4)
3.3.2 Machine controller
Name
SIMATIC Microbox 420
CPU / clock frequency
Pentium III / 933 MHz
RAM
256 MB
Hard disk
40 GB
Serial interfaces 1
Network
2x 100 MBit
Table 3-5: Machine controller hardware (SIPLACE D4)

Installation Manual, Station Software Version 602.01 Edition 06/2006
3.4 Network configuration
Station computer
Machine controller
10Base-T
100Base-T
Private network between
station computer and
machine controller
SIPLACE LAN
SIPLACE Pro
Twisted Pair TP
(100 MB)
Twisted Pair TP
(10 MB)
Fig. 3-3: Network connections between the machine and SIPLACE Pro
A separate private network (100 Mbit) is set up between the station computer and the machine controller
via a subnet mask.
Fixed IP addresses for the station computer and the machine controller can thus be assigned for all
SIPLACE machines. These IP addresses are not known outside the private network, for instance in the
SIPLACE LAN.
These IP addresses need not be further configured by the operator while the station software is being
installed.
IP address, station computer 192.168.255.249
IP address, machine controller 192.168.255.250
Subnet mask, station computer/machine controller 255.255.255.248
IP address range, SIPLACE LAN 172.22.xxx.xxx
Subnet mask, SIPLACE LAN 255.255.0.0
Table 3-6: Network configuration
16 of 60

Installation Manual, Station Software Version 602.01 Edition 06/2006
4 Installation Manual
4.1 Installation procedure
See sections
4.2.1 and 4.2.2
See sections 4.2.3, 4.2.4 and 4.2.5
See sections
4.2.1 and 4.2.2
See sections
4.2.3 (for CPU076), 4.2.4 (for CPU086) and 4.2.5
(for CPU420)
See separate "Installation Manual for Windows XP";
For calibration of the touchscreen, see section
4.3.1.2 for the
X-Series and
4.3.1.3 for the D-Series
See sections
4.6.1 (for CPU076), 4.8.1 (for CPU086) and 4.9.1
(for CPU420)
See section
4.3
17 of 60