00192267-02 - 第30页

HS-50 Changeover Instructions Cont rol PCB Convey or 2.4 Assembly and Wiring 04/2002 Issue 30 : pin up all remai ning cabl e in acc ordanc e with con veyor 1 / 2 to the co rrespo nding co nversa tion board (plug na mes f…

100%1 / 46
Changeover Instructions Control PCB Conveyor HS-50
04/2002 Issue 2.4 Assembly and Wiring
29
 $VVHPEO\DQG:LULQJ
: disconnect complete wiring of Conveyor Control and SLIOs;
: disconnect grounding cords (grounding mounting plate - machine base);
: remove mounting plate and changeover kit (assemble single/double conveyor, fixture points
identical);
: remove old cable power supply "conveyor control" (Mat.-No.: 00335234) and "SLIO conveyor"
(Mat.-No.: 00335233) (these are no longer required);
: connect the new cable power supply (component of the changeover kit) to the plug X79;
: ,PSRUWDQW6FUHZWKHJURXQGLQJFRUGRQWRWKHPDFKLQHEDVH
DUUDQJHPHQWVHHEHORZ
: connect available CAN-Bus cable (00335323) to the CAN connection of the conveyor controls
(Please note: the plug markings on the available CAN-Bus cable are not identical to the names
on the controls, therefore the following procedure:
last plug on the cable (X18am) to the CAN connection of the control conveyor 1 (X22ao);
penultimate plug on the cable (X34ao) to the CAN connection of the control conveyor 2
(X22ap);
: The control signals for the motor lifting tables X3 / X6 (cable 00333592) must be plugged to the
associated pin contacts on the conveyor control.
Please note: both plugs are coded the same, therefore there is the danger of them being mixed
up, pay attention to the markings.
WARNING
If the plugs of the interface cord to precedent/following machine are connected incorrectly the con-
veyor controls can be damaged: The plugs of the old conveyor control TSP100 are not coded.
Please pay attention to the Pin1 markings on the board.
HS-50 Changeover Instructions Control PCB Conveyor
2.4 Assembly and Wiring 04/2002 Issue
30
: pin up all remaining cable in accordance with conveyor 1 / 2 to the corresponding conversation
board
(plug names for conveyor 1 with ending DPDR;
plug names for conveyor 2 with the ending DQDS);
The associated conversation board also has the corresponding module names;
: wire interface cable according to the name on the conveyor control;
: check coding of the controls and the jumper positions (according to assignment list in the cover
/ sticker on the mounting plate);
: load firmware conveyor control (see ch. 3);
: attach ESD covers via control, turn on machine.
Changeover Instructions Control PCB Conveyor HS-50
04/2002 Issue 2.5 Schematics and Settings
31
 6FKHPDWLFVDQG6HWWLQJV
On the following pages an abstract of circuit diagrams and additional information considering jum-
per settings on the boards.