HS50_advance_level 1_20200522_221201 (1) - 第151页

Studen t Guide HS-50 A dvanced I 06/200 2 Edition 5 DLM1 C&P Head 59 ➠ Carefully remove the hose from the pressure sensor (see item 4 in F ig. 5.4 - 17 ). ➠ Remove the following pl ugs from their sockets on th e boar…

100%1 / 567
06/2002 Edition Student Guide HS-50 Advanced I
5 DLM1 C&P Head
58
5.4.9.3 Dismantling the intermediate distribution board
5
Fig. 5.4 - 17 Dismantling the intermediate distribution board
Key to Fig. 5.4 - 17
(1) Intermediate distribution board
(2) M3x5 hexagon socket-head screw
(3) 3 x M3x10 spacer bolt
(4) Pressure sensor
(5) Head board
5
Switch the placement system off and secure it to prevent switching on again as described in
section 5.4.1
, page - 32.
Undo the M3x5 hexagon socket-head screw (see item 2 in Fig. 5.4 - 17).
Remove the three M3x10 spacer bolts (item 3 in Fig. 5.4 - 17) and tilt the PCB slightly (item 1
in Fig. 5.4 - 17
).
Student Guide HS-50 Advanced I 06/2002 Edition
5 DLM1 C&P Head
59
Carefully remove the hose from the pressure sensor (see item 4 in Fig. 5.4 - 17).
Remove the following plugs from their sockets on the board (see Fig. 5.4 - 18 on page 5 - 59).
Remove the intermediate distribution board.
5
Fig. 5.4 - 18 Sockets on the intermediate distribution board
5.4.9.4 Dismantling the star
Dismantle the front part of the collect&place head as described in section 5.4.3, page - 36
onwards.
Place the front part of the collect&place head on the tray.
X1 Ribbon cable at X14 on the head board
X2 Ribbon cable at X13 on the head board
X3 Motor / tacho connection for the Z-axis
X4 Measuring system connection for the Z-axis
X5 Motor connection for the star axis
X6 Connection for the "Forced air unit" valve
X7 Measuring system connection for the DP-axis
X10 Connection for the "Z-axis up" light barrier (adjustment unit)
X11 Connection for the "Z-axis down" light barrier
X12 Measuring system connection for the star axis
Tab. 5.4 - 2 Sockets on the intermediate distribution board
06/2002 Edition Student Guide HS-50 Advanced I
5 DLM1 C&P Head
60
PLEASE NOTE:
Wear laboratory gloves when you remove the sleeves from the star.
Remove all the sleeves (item 1 in Fig. 5.4 - 8) and place them in the sleeve box or on a soft,
clean surface.
Undo the three M3x8 hexagon socket head screws (item 5 in Fig. 5.4 - 8).
Raise the star slightly.
Use a rotary movement to lift the star up and off.
5
Fig. 5.4 - 19 Replacing the star
(1) Sleeve
(2) Star, mounted / DLM1
(3) Star drive
(4) Front part of collect&place head
(5) M3x8 hexagon socket head screws, 3x
(6) Segment
(7) Raceway