HS50_advance_level 1_20200522_221201 (1) - 第156页

06/2002 E dition Studen t Guide H S-50 Advance d I 5 DLM1 C&P H ead 64 5.4. 9.9 Fitting t he front p art of t he col lect&place head ➠ Remove th e gauge for the star . ➠ Insert t he power cab le plug connector f …

100%1 / 567
Student Guide HS-50 Advanced I 06/2002 Edition
5 DLM1 C&P Head
63
CAUTION
The maximum operating time of the power pack for the star motor is five minutes. Do NOT
exceed this time. If you have to disconnect the power pack from the power source because
it has been operating for five minutes, always insert the gauge pin before switching the power
pack on again. 5
If you still cannot fit the star in the magnetic neutral position of the star motor, follow the
instructions below: 5
Loosen the four M5x16 hexagon socket head screws (item 2 in Fig. 5.4 - 9) for fixing the star
drive (item 1 in Fig. 5.4 - 9
) and turn the star drive in the direction that will allow the star to be
adjusted with respect to the magnetic neutral position. Tighten the four hexagon socket head
screws in this position.
5
Fig. 5.4 - 21 Loosening the star drive
(1) Star drive, digital / DLM1
(2) M5x16 hexagon socket head screws, 4x
(3) Front part of collect&place head
Loosen the three M3x8 hexagon socket head screws (item 5 in Fig.
5.4 - 8
) for fixing the star again and repeat the adjustment procedure.
PLEASE NOTE:
The star is fitted correctly until it no longer moves out of position when the gauge pin is
removed after disconnecting the star drive from the power supply. 5
06/2002 Edition Student Guide HS-50 Advanced I
5 DLM1 C&P Head
64
5.4.9.9 Fitting the front part of the collect&place head
Remove the gauge for the star.
Insert the power cable plug connector for the star drive into socket X5 on the intermediate
terminal block. The plug connector is an anti-rotation connector.
Fit the front part of the collect&place head on the back part of the collect&place head (see
section 5.4.3.3
, page 5 - 39).
5.4.9.10 Fitting the intermediate distribution board
Restore connections X1 ... X12 as described in Table 5.4 - 2.
Push the hose onto the pressure sensor tube (see item 4 in Fig. 5.4 - 17).
Fix the intermediate distribution board in place (see item 2 and 3 in Fig. 5.4 - 17).
Fix the protective cover to the head.
Switch the placement system on and start it up.
5.4.10 Replacing the RSF digital rotary encoder 12/DLM1
5.4.10.1 Tools and equipment
Set of DIN 911 Allen keys
Gauge for the star (collect&place head / DLM1), article number 00326164-01
Test probe, 1.5 mm, article number 00326161-01
Power pack for the collect&place head / DLM1, article number 00353277-01
Tray for transporting the collect&place head
Laboratory gloves
5.4.10.2 Parts
RSF digital rotary encoder 12/DLM1 article number 00335990-02 5
5.4.10.3 Dismantling the rotary encoder
Dismantle the front part of the collect&place head as described in section 5.4.3, page - 36
onwards.
Dismantle the star as described in section 5.4.5.3
, page 5 - 43 onwards.
Remove the black blanking cap over the RSF board (item 4 in Fig. 5.4 - 22
).
Remove the plug connector (item X7 in Fig. 5.4 - 22
) from socket X7 on the intermediate
terminal block.
Student Guide HS-50 Advanced I 06/2002 Edition
5 DLM1 C&P Head
65
Undo the two M2.5x4 hexagon socket-head screws (item 5 in Fig. 5.4 - 22) for fixing the RSF
board.
Undo the two M2.5x8 hexagon socket-head screws (item 3 in Fig. 5.4 - 22
) and remove the
rotary encoder.
5
Fig. 5.4 - 22 Dismantling / fitting the rotary encoder
(1) Front part of collect&place head
(2) RSF digital rotary encoder 12/DLM1
(3) M2.5x8 hexagon socket head screws, 2x
(4) RSF board, type 950
(5) M2.5x4 hexagon socket head screws, 2x
X7 Plug connector in socket X7 on the intermediate terminal block 5
5