Studen t Guide HS-50 A dvanced I 06/200 2 Edition 6 Operat ing the S ITE ST S o ftware 37 6. 6 .3 S et t ing th e C onveyor Sp ee d Here, th e conveyor s peed may be s et to the default value. Enter the default v alue wi…

100%1 / 567
06/2002 Edition Student Guide HS-50 Advanced I
6 Operating the SITEST Software
36
6.6.2 Conveyor Width Settings
Measure conveyor width
Measures the current conveyor
width and displays the value
above the applicable button.
Adjusting the conveyor width
Width-out
The width of the conveyors will be increased when the button is
actuated.
Width-out (high speed)
The width of the conveyors is increased at high speed when the
button is actuated.
Calibrate conveyor width
Determines the gantry position for a 100mm wide PCB.
Width-in
The width of the conveyors will be decreased when the button is
actuated.
Width-in (high speed)
The width of the conveyors is decreased at high speed when the
button is actuated.
Call-up the Conveyor Functions
view.
Call-up the screen for setting
the conveyor speed.
Not for SIPLACE S-25HM!
Call-up of the display of the
conveyor width settings.
Call-up the screen displaying
the PCB transport functions.
Return to the main view.
Selects PCB conveyor 1/2
(in the case of dual lane
conveyors).
Width [mm/10]
Enter the desired conveyor
width (within the specified value
range) in the data entry field.
Student Guide HS-50 Advanced I 06/2002 Edition
6 Operating the SITEST Software
37
6.6.3 Setting the Conveyor Speed
Here, the conveyor speed may be set
to the default value.
Enter the default value within the
specified value limits.
Save speeds
This function is only active if the
conveyor speed was changed or set to
a default value.
Call-up the Conveyor Functions
view.
Call-up the screen for setting
the conveyor speed.
Not for SIPLACE S-25HM!
Call-up of the display of the
conveyor width settings.
Call-up the screen displaying
the PCB transport functions.
Return to the main view.
Selects PCB conveyor 1/2
(in the case of dual lane
conveyors).
Here, the conveyor speed
may be changed.
Enter the speed within the
specified value limits.
Not for SIPLACE S-25 HM
Conveyor speeds
Retract
Selects the input conveyor.
Extend
Selects the output conveyor.
Standard
Selects all conveyors.
Positioning
Selects the center conveyor.
Test speed
The conveyor continues operating until
operation is disrupted. The speed of the
selected conveyor is tested when so doing.
06/2002 Edition Student Guide HS-50 Advanced I
6 Operating the SITEST Software
38
6.6.4 Conveyor Functions
Call-up the Conveyor Functions
view.
Call-up the screen for setting
the conveyor speed.
Not for SIPLACE S-25HM!
Call-up of the display of the
conveyor width settings.
Call-up the screen displaying
the PCB transport functions.
Return to the main view.
Selects PCB conveyor 1/2
(in the case of dual lane
conveyors).
Barcode reader
Load PCB
Activated: The conveyor automatically
transports the PCB through the machine.
Deactivated: The PCB needs to be moved
through the machine manually.
Position
Indicates whether the barcode was read off
the bottom or the top of the PCB.
Barcode 01-20
Displays the first 20 characters of a
barcode with max. 40 digits.
Barcode 21-40
Displays the characters 21-40 of a barcode
with max. 40 digits.