06/2002 E dition Studen t Guide H S-50 Advance d I 7 Calibr ation 18 0 fi g 7.3 - 22 S av e ma ch in e da ta 7.3. 10 Save Ma ch ine D ata

Student Guide HS-50 Advanced I 06/2002 Edition
7 Calibration
17
0
7.3.9.6 Minimum Traversing Path X-Axis Gantry 1 (4)
à Manually, move the gantry 1 (4) towards the deflection unit X, until both proximity switches are off.
à Now, manually move gantry 1 (4) towards the X-motor, until a proximity switch just is on.
SITEST: 7
à Select "Gantry" ==> "Gantry 1 (4) ==> "Axis Functions" ==> "X-axis" ==>
"Positions ...".
à Edit the value for the current position of the x-axis under "Minimum position [dgts]" and accept the value.
à Perform a reference run.
à Select "Main View" ==> "Settings" ==> "Save machine data".
7.3.9.7 Maximum Traversing Path X-Axis Gantry 2 (4)
à Manually, move gantry 2 (4) towards deflection unit-X, until both proximity switches are off.
à Now, manually move gantry 1 (4) towards the x-motor, until a proximity switch is on.
SITEST: 7
à Select "Gantry" ==> "Gantry 2 (4) ==> "Axis Functions" ==> "X-axis" ==>
"Positions ...".
à Edit the value for the current position of the x-axis under "Maximum position [dgts]" and accept the value.
à Perform a reference run.
à Select "Main View" ==> "Settings" ==> "Save machine data".
7.3.9.8 Minimum Traversing Path X-Axis Gantry 3 (4)
à Manually, move gantry 3 (4) towards the deflection unit-X, until both proximity switches are off.
à Now, manually move gantry 3 (4) towards the x-motor, until a proximity switch just is on.
SITEST: 7
à Select "Gantry" ==> "Gantry 3 (4) ==> "Axis Functions" ==> "X-axis" ==>
"Positions ...".
à Edit the value for the current position of the x-axis under "Minimum position [dgts]" and accept the value.
à Perform a reference run.
à Select "Main View" ==> "Settings" ==> "Save machine data".

06/2002 Edition Student Guide HS-50 Advanced I
7 Calibration
18
0
fig 7.3 - 22 Save machine data
7.3.10 Save Machine Data

Student Guide HS-50 Advanced I 06/2002 Edition
19
7.4 Machine Offsets and their interrelationships
1
©
PL EA 1 V GC Training
Version Dec / 00
Calibration of SIPLACE HS-50
Whenever mechanical repair work has been done:
Ø for proper operation of the machine mechanical
adjustments are necessary and
Ø for the placement accuracy within our
specification some functions must been
meassured / calibrated.