HS50_advance_level 1_20200522_221201 (1) - 第266页

\ X-Offset in microns \ 3, Fine calibration offset X of gantry 2 -is determined for the 12 nozzle head - with Standard component camera- for Transport 1 \ Y-Offset in microns \ -4, Fine calibration offset Y of gantry 2 -…

100%1 / 567
\ Y-Offset in microns \ 0,
Fine calibration offset Y of gantry 1 -is determined for the 12 nozzle head - with
Standard component camera- for Transport 2
\ Winkel-Offset in 1/100 Grad \ 0>
\ 02. Datensatz \
\ ID-Name \ "SEGMENT_01";
\ 1. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0!
\ 2. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0>
Printout shortend because of Layout
\ ID-Name \ "SEGMENT_12";
\ 1. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0!
\ 2. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0]
\ Datensatz 3. BE-Kamera \
\ KameraID \ 3012#
30xx is gantry 3 12 is Standard component camera 32 x 32 mm
\ KameraTyp \ "RV12CamP3"#
Fine calibration values are only measured for component camera
s
\ Level \ 1#
\ Anzahl der Saetze \ 13#
\ 01. Datensatz \
only the data set 01 with ID-name "global" is valid
\ ID-Name \ "GLOBAL";
\ 1. Transport \
\ X-Offset in microns \ -15,
Fine calibration offset X of gantry 3 -is determined for the 12 nozzle head - with
Standard component camera- for Transport 1
\ Y-Offset in microns \ 10,
Fine calibration offset Y of gantry 3 -is determined for the 12 nozzle head - with
Standard component camera- for Transport 1
\ Winkel-Offset in 1/100 Grad \ 0!
\ 2. Transport \
\ X-Offset in microns \ -7,
Fine calibration offset X of gantry 3 -is determined for the 12 nozzle head - with
Standard component camera- for Transport 2
\ Y-Offset in microns \ 0,
Fine calibration offset Y of gantry 3 -is determined for the 12 nozzle head - with
Standard component camera- for Transport 2
\ Winkel-Offset in 1/100 Grad \ 0>
\ 02. Datensatz \
\ ID-Name \ "SEGMENT_01";
Printout shortend because of Layout
\ 13. Datensatz \
\ ID-Name \ "SEGMENT_12";
\ 1. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0!
\ 2. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0]
\ Datensatz 4. BE-Kamera \
\ KameraID \ 2012#
20xx is gantry 2 12 is Standard component camera 32 x 32 mm
\ KameraTyp \ "RV12CamP2"#
Fine calibration values are only measured for component camera
s
\ Level \ 1#
\ Anzahl der Saetze \ 13#
\ 01. Datensatz \
only the data set 01 with ID-name "global" is valid
\ ID-Name \ "GLOBAL";
\ 1. Transport \
Edition 1.0 2 FK_OFF_MA_e.xls FK_OFF.MA SD EA1 S GC Training
\ X-Offset in microns \ 3,
Fine calibration offset X of gantry 2 -is determined for the 12 nozzle head - with
Standard component camera- for Transport 1
\ Y-Offset in microns \ -4,
Fine calibration offset Y of gantry 2 -is determined for the 12 nozzle head - with
Standard component camera- for Transport 1
\ Winkel-Offset in 1/100 Grad \ 0!
\ 2. Transport \
\ X-Offset in microns \ -18,
Fine calibration offset X of gantry 2 -is determined for the 12 nozzle head - with
Standard component camera- for Transport 2
\ Y-Offset in microns \ 23,
Fine calibration offset Y of gantry 2 -is determined for the 12 nozzle head - with
Standard component camera- for Transport 2
\ Winkel-Offset in 1/100 Grad \ 0>
\ 02. Datensatz \
\ ID-Name \ "SEGMENT_01";
Printout shortend because of Layout
\ 13. Datensatz \
\ ID-Name \ "SEGMENT_12";
\ 1. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0!
\ 2. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0]
\ Datensatz 5. BE-Kamera \
No other component cameras at the HS5X mounted. So no other Fine calibration
offset to determine.
\ KameraID \ 0#
\ KameraTyp \ #
\ Level \ 0#
\ Anzahl der Saetze \ 0#
\ 01. Datensatz \
\ ID-Name \ ;
\ 1. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0!
\ 2. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0>
\ 02. Datensatz \
\ ID-Name \ ;
\ 1. Transport \
Printout shortend because of Layout
\ Datensatz 6. BE-Kamera \
No other component cameras at the HS5X mounted. So no other Fine calibration
offset to determine.
\ KameraID \ 0#
\ KameraTyp \ #
\ Level \ 0#
\ Anzahl der Saetze \ 0#
\ 01. Datensatz \
\ ID-Name \ ;
\ 1. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0!
\ 2. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0>
\ 02. Datensatz \
Printout shortend because of Layout
Edition 1.0 3 FK_OFF_MA_e.xls FK_OFF.MA SD EA1 S GC Training
\ Datensatz 7. BE-Kamera \
No other component cameras at the HS5X mounted. So no other Fine calibration
offset to determine.
\ KameraID \ 0#
\ KameraTyp \ #
\ Level \ 0#
\ Anzahl der Saetze \ 0#
\ 01. Datensatz \
\ ID-Name \ ;
\ 1. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0!
\ 2. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0>
\ 02. Datensatz \
Printout shortend because of Layout
\ Datensatz 8. BE-Kamera \
No other component cameras at the HS5X mounted (e.g. DCA camera). So no
other Fine calibration offset to determine.
\ KameraID \ 0#
\ KameraTyp \ #
\ Level \ 0#
\ Anzahl der Saetze \ 0#
\ 01. Datensatz \
\ ID-Name \ ;
\ 1. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0!
\ 2. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0>
\ 02. Datensatz \
Printout shortend because of Layout
\ 13. Datensatz \
\ ID-Name \ ;
\ 1. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0!
\ 2. Transport \
\ X-Offset in microns \ 0,
\ Y-Offset in microns \ 0,
\ Winkel-Offset in 1/100 Grad \ 0
}
end of file
Edition 1.0 4 FK_OFF_MA_e.xls FK_OFF.MA SD EA1 S GC Training