HS50_advance_level 1_20200522_221201 (1) - 第270页

\ ** Kamera_Offset_Winkel ** \ 8, PCB camera mounting angle on the gantry. calibrated with SITEST \ XU_Pixel \ 11571, Pixel size in X direction in nm. calibrated with SITEST \ YU_Pixel \ 11546] Pixel size in Y direction …

100%1 / 567
\ ** Kamera_Offset_Z ** \ 0,
The camera do not have an Angle Offset, here always 0.(each camera
have an mounting angle)
\ ** Kamera_Offset_Winkel ** \ -3,
comp. camera mounting angle to the turning level of the placement STAR.
calibrated with SITEST
\ XU_Pixel \ 49494,
Pixel size in X direction in nm. calibrated with SITEST
\ YU_Pixel \ 49434]
Pixel size in Y direction in nm. calibrated with SITEST
\ Kamerabeschreibung 4. Kamera \
\ Sensorsystem_Individuum_Nr \ 1012,
Standard-comp.-camera gantry 1
\ Auswerte_Nr \ 1,
connection to Vision controller (MVS-System) for working area 1
\ Kanal-Nummer \ 3,
Input coding >channel< at Visionsystem. Same connector than ch.1
\ *** Nachschwingzeit *** \ 0,
waiting time only valid for PCB-camera
\ ** Korrekturfaktor_A_X ** \ -3,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_B_X ** \ -49366,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_C_X ** \ 0,
by standard 0
\ ** Korrekturfaktor_A_Y ** \ -13,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_B_Y ** \ -49294,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_C_Y ** \ 0,
by standard 0
\ ** Kamera_Offset_X ** \ 0,
PCB-camera -comp.-camera-offset reference is comp.camera so here is
always 0
\ ** Kamera_Offset_Y ** \ 0,
PCB-camera -comp.-camera-offset reference is comp.camera so here is
always 0
\ ** Kamera_Offset_Z ** \ 0,
The camera do not have an Angle Offset, here always 0.(each camera
have an mounting angle)
\ ** Kamera_Offset_Winkel ** \ 2,
comp. camera mounting angle to the turning level of the placement STAR.
calibrated with SITEST
\ XU_Pixel \ 49366,
Pixel size in X direction in nm. calibrated with SITEST
\ YU_Pixel \ 49294]
Pixel size in Y direction in nm. calibrated with SITEST
\ Kamerabeschreibung 5. Kamera \
(first the left gantry of the working area)
\ Sensorsystem_Individuum_Nr \ 3005,
3. mean gantry 3 5 is Type nr. of the Standard-PCB-camera
\ Auswerte_Nr \ 2,
Vision system for the 2nd working area
\ Kanal-Nummer \ 2,
all cameras of 3rd gantry on connector >channel< 2/4
\ *** Nachschwingzeit *** \ 50,
waiting time (in msec. until oscillating of the gantry stopped) before start to
read out the CCD Sensor of PCB-camera
\ ** Korrekturfaktor_A_X ** \ 108,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_B_X ** \ -11540,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_C_X ** \ 0,
by standard 0
\ ** Korrekturfaktor_A_Y ** \ 107,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_B_Y ** \ 11552,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_C_Y ** \ 0,
by standard 0
\ ** Kamera_Offset_X ** \ -36,
PCB-camera -comp.-camera-offset calibrated with Segment 1 at Segment
Offset bottom
\ ** Kamera_Offset_Y ** \ 101032,
PCB-camera -comp.-camera-offset calibrated with Segment 1 at Segment
Offset bottom
\ ** Kamera_Offset_Z ** \ 0,
The camera do not have an Angle Offset, here always 0.(each camera
have an mounting angle)
\ ** Kamera_Offset_Winkel ** \ 53,
PCB camera mounting angle on the gantry. calibrated with SITEST
\ XU_Pixel \ 11541,
Pixel size in X direction in nm. calibrated with SITEST
\ YU_Pixel \ 11553]
Pixel size in Y direction in nm. calibrated with SITEST
\ Kamerabeschreibung 6. Kamera \
\ Sensorsystem_Individuum_Nr \ 2005,
2 mean gantry 2 5 is Type nr. of the Standard-PCB-camera
\ Auswerte_Nr \ 2,
Vision system for the 2nd working area
\ Kanal-Nummer \ 1,
all cameras of 2nd gantry on connector >channel< 1/
3
\ *** Nachschwingzeit *** \ 50,
waiting time (in msec. until oscillating of the gantry stopped) before start to
read out the CCD Sensor of PCB-camera
\ ** Korrekturfaktor_A_X ** \ 17,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_B_X ** \ -11571,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_C_X ** \ 0,
by standard 0
\ ** Korrekturfaktor_A_Y ** \ 16,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_B_Y ** \ 11546,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_C_Y ** \ 0,
by standard 0
\ ** Kamera_Offset_X ** \ -191,
PCB-camera -comp.-camera-offset calibrated with Segment 1 at Segment
Offset bottom
\ ** Kamera_Offset_Y ** \ 100833,
PCB-camera -comp.-camera-offset calibrated with Segment 1 at Segment
Offset bottom
\ ** Kamera_Offset_Z ** \ 0,
The camera do not have an Angle Offset, here always 0.(each camera
have an mounting angle)
Edition 1.0 2 KAMDAT_MA_e.xls KAMDAT.MA SD EA1 S GC Training
\ ** Kamera_Offset_Winkel ** \ 8,
PCB camera mounting angle on the gantry. calibrated with SITEST
\ XU_Pixel \ 11571,
Pixel size in X direction in nm. calibrated with SITEST
\ YU_Pixel \ 11546]
Pixel size in Y direction in nm. calibrated with SITEST
\ Kamerabeschreibung 7. Kamera \
\ Sensorsystem_Individuum_Nr \ 3012,
3. mean gantry 3 12 is Type nr. of the Standard-component-camer
a
\ Auswerte_Nr \ 2,
Vision system for the 2nd working area
\ Kanal-Nummer \ 4,
all cameras of 3rd gantry on connector >channel< 2/4
\ *** Nachschwingzeit *** \ 0,
waiting time valid only for PCB-camera
\ ** Korrekturfaktor_A_X ** \ -11,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_B_X ** \ 49370,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_C_X ** \ 0,
by standard 0
\ ** Korrekturfaktor_A_Y ** \ 14,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_B_Y ** \ 49329,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_C_Y ** \ 0,
by standard 0
\ ** Kamera_Offset_X ** \ 0,
for PCB-camera -comp.-camera-offset is the comp. camera the reference
so here is always 0.
\ ** Kamera_Offset_Y ** \ 0,
for PCB-camera -comp.-camera-offset is the comp. camera the reference
so here is always 0.
\ ** Kamera_Offset_Z ** \ 0,
The camera do not have an Angle Offset, here always 0.(each camera
have an mounting angle)
\ ** Kamera_Offset_Winkel ** \ 1,
Component camera mounting angle to the turning level of the placement
STAR. calibrated with SITEST
\ XU_Pixel \ 49370,
Pixel size in X direction in nm. calibrated with SITEST
\ YU_Pixel \ 49329]
Pixel size in Y direction in nm. calibrated with SITEST
\ Kamerabeschreibung 8. Kamera \
\ Sensorsystem_Individuum_Nr \ 2012,
2. mean gantry 2 12 is Type nr. of the Standard-component-camer
a
\ Auswerte_Nr \ 2,
Vision system for the 2nd working area
\ Kanal-Nummer \ 3,
all cameras of 2nd gantry on connector >channel< 1/
3
\ *** Nachschwingzeit *** \ 0,
waiting time valid only for PCB-camera
\ ** Korrekturfaktor_A_X ** \ -199,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_B_X ** \ 49123,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_C_X ** \ 0,
by standard 0
\ ** Korrekturfaktor_A_Y ** \ 204,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_B_Y ** \ 49141,
to calculate the pixel size by matirix math. calibrated with SITEST
\ ** Korrekturfaktor_C_Y ** \ 0,
by standard 0
\ ** Kamera_Offset_X ** \ 0,
for PCB-camera -comp.-camera-offset is the comp. camera the reference
so here is always 0.
\ ** Kamera_Offset_Y ** \ 0,
for PCB-camera -comp.-camera-offset is the comp. camera the reference
so here is always 0.
\ ** Kamera_Offset_Z ** \ 0,
The camera do not have an Angle Offset, here always 0.(each camera
have an mounting angle)
\ ** Kamera_Offset_Winkel ** \ -56,
Component camera mounting angle to the turning level of the placement
STAR. calibrated with SITEST
\ XU_Pixel \ 49123,
Pixel size in X direction in nm. calibrated with SITEST
\ YU_Pixel \ 49141
Pixel size in Y direction in nm. calibrated with SITEST
}
Edition 1.0 3 KAMDAT_MA_e.xls KAMDAT.MA SD EA1 S GC Training
\ ## File converted by makonv at Wed Nov 21 13:37:20 2001 \
{
from KONFIG.Area of DataBase is with Data converting the correct
KONFIG.MA created.
\ Dateiprolog \
\ Datei \ "KONFIG.MA"|
configuration of the station
\ Version \ "31.503.011119_E"|
\ Maschinentyp \ "HS50"|
\ Pruefsumme \
\ Pruefsummen Eintrag \ -1|
\ Portalkonfiguration \
\ Beschreibung 1. Portalgruppe \
descriptions of parts in working area 1
\ Portalgruppentyp \ 1]
\ Portalgruppen-ID \ 1]
number of working area
\ Beschreibung 1. Portal \
left gantry at working area 1 of the HS50 is gantry 1 of a S25 HM gantry
arrangement
\ Portaltyp \ 1]
\ Portal-ID \ 4]
gantry 4
\ Lage-Portal \ 1]
\ BE-Abwurfposition \ 0]
\ Beschreibung 1. Achse \
\ Achstyp \ 520,
5 mean HS 5X / 2 is gantry axis / 0 is X-Axis
\ Achs-ID \ 30,
only a numberin
g
\ Achsennummer \ 9,
A
xis address X axis gantry 4 at the 4. Axis controller board
\ Achs-Modus \ 1,
\ Beschreibung 2. Achse \
\ Achstyp \ 521,
5 mean HS 5X / 2 is gantry axis / 1 is Y-Axis
\ Achs-ID \ 31,
only a numberin
g
\ Achsennummer \ 10,
A
xis address Y axis gantry 4 at the 4. Axis controller board
\ Achs-Modus \ 1]
\ Beschreibung 1. Kopf \
\ Kopftyp \ 5]
12 nozzle RV-hea
d
\ Kopf-ID \ 4]
\ Beschreibung 1. Achse \
\ Achstyp \ 502,
5 mean HS 5X (12nozzle-Kopf) / 0 is head axis / 2 is Star-Axi
s
\ Achs-ID \ 32,
\ Achsennummer \ 11,
A
xis address STAR axis gantry 4 at the 4. Axis controller board
\ Achs-Modus \ 1#
\ Beschreibung 2. Achse \
\ Achstyp \ 503,
5 mean HS 5X (12nozzle-Kopf) / 0 is head axis / 3 is Z-Axi
s
\ Achs-ID \ 33,
\ Achsennummer \ 18,
A
xis address Z-Axis gantry 4 at the 7. Axis controller board
\ Achs-Modus \ 1#
\ Beschreibung 3. Achse \
\ Achstyp \ 504,
5 mean HS 5X (12nozzle-Kopf) / 0 is head axis / 4 is DP-Axi
s
\ Achs-ID \ 34,
\ Achsennummer \ 19,
A
xis address DP-Axis gantry 4 at the 7. Axis controller board
\ Achs-Modus \ 1]
\ Beschreibung 1 Pipettenwechsler \
\ Pipettenwechslertyp \ 0]
Standard nozzle changer type for 12 nozzle -RV-head of the HS 5
X
\ Sensorsystem Id's /Kopf \ 4012: -1: -1,
at gantry 4 a 12 noz.RV-comp.-camera / -1 no other camer
a
\ Beschreibung 2. Kopf \
\ Kopftyp \ -1]
NO
2
n
d
placement head is installed at gantry at HS 5X /S25 HM X
\ Kopf-ID \ -1]
\ Beschreibung 1. Achse \
\ Achstyp \ -1,
\ Achs-ID \ -1,
\ Achsennummer \ -1,
\ Achs-Modus \ -1#
\ Beschreibung 2. Achse \
\ Achstyp \ -1,
\ Achs-ID \ -1,
\ Achsennummer \ -1,
\ Achs-Modus \ -1#
\ Beschreibung 3. Achse \
\ Achstyp \ -1,
\ Achs-ID \ -1,
\ Achsennummer \ -1,
\ Achs-Modus \ -1]
KONFIG_MA_e.xls KONFIG.MA SD EA1 S GC Training