Studen t Guide HS-50 A dvanced I 06/200 2 Edition 1 Safet y Consider ation 13 1.4 Flow ch art Protective circuit Fig. 1.4 - 1 flow chart "Prot ective c irc uit"

100%1 / 567
06/2002 Edition Student Guide HS-50 Advanced I
1 Safety Consideration
12
1.3 Safety Circuit HS-50
The following conditions must be fullfilled before starting or operating the HS-50
All four component change over tables must be docked and connected.
All six protective hoods must be closed
Both Emergency Stop buttons must be unlocked
All four component protective flaps covering the buttons
for raising and lowering the component changeover table
must be closed.
The minimum operating pressure 5,5 bar must be reached
The software must be released
Student Guide HS-50 Advanced I 06/2002 Edition
1 Safety Consideration
13
1.4 Flow chart Protective circuit
Fig. 1.4 - 1 flow chart "Protective circuit"
06/2002 Edition Student Guide HS-50 Advanced I
1 Safety Consideration
14