HS50_advance_level 1_20200522_221201 (1) - 第309页

{ comment for the 'IDEAL.MA'. file version of HS50 machine type \Stationsname\ a new format for 503 SW ! With german comment in 1 s t column SIPL_HS50 customer defined station name of HS50 station from LC | \Ma…

100%1 / 567
} end of file
Edition 1.0 5 REAL_MA_e.xls REAL.MA SD EA1 S GC Training
{
comment for the 'IDEAL.MA'. file version of HS50 machine type
\Stationsname\
a new format for 503 SW ! With german comment in 1
s
t
column
SIPL_HS50
customer defined station name of HS50 station from LC
|
\Maschinenoptionen\
machine option
s
\CRDL_K1\ 0,
CRDL on head1 (only at S15 / F 3 )
\CRDL_K2\ 0,
CRDL on head2 (only at S15 / F 3 )
\BEZ_Vision_K1\ 1,
comp.-centering with Vision at head 1 working area BB1
\BEZ_Vision_K2\ 1,
comp.-centering with Vision at head 2 working area BB1
\Pipettenwechsler_K11\ 1,
nozzle changer at head
1
\Pipettenwechsler_K12\ 1,
nozzle changer at head
2
\Sync_Doppeltransport\ 0,
kind of transport; 0 is asynchron - 1 is synchron double-transport
\Transportanschlag\ 0,
fixed transport side 0 is right-; 1 is left side fixed
\Koplanaritaet_K1\ 0,
coplanarity head 1 (because of format in)
\Koplanaritaet_K2\ 0,
coplanarity head 1 (because of format in)
\LP_Barcode_Leser\ 0,
PCB-Barcode reader optio
n
\Nachfuell_Barcode_Leser\ 1,
component refill-Barcode-reader optio
n
\BEZ_Mechanisch_K1\ 0,
mechanic comp. centering head 1 (for historic reasons)
\BEZ_Mechanisch_K2\ 0,
mechanic comp. centering head 1 (for historic reasons)
\BE-Entsorgung_K11\ 0,
comp.-removal unit head1 at working area BB 1 (mean gantry 1 at S2X /
gantry 4 at HS5X)
\BE-Entsorgung_K12\ 0,
comp.-removal unit head2 (mean gantry2 at S2X / gantry1 an HS5X)
\BE-Entsorgung_K21\ 0,
comp.-removal unit head1 in working area BB2 mean gantry3 at HS5X
\BE-Entsorgung_K22\ 0,
comp.-removal unit head 2 BB2 mean gantry2 at HS5
X
\BEZ_Vision_K21\ 1,
comp.-centering with vision K21 mean work area BB 2 right gantry 3 at
HS5X
\BEZ_Vision_K22\ 1,
comp.-centering with vision K22 mean work area BB 2 right gantry 2 at
HS5X
\Pipettenwechsler_K21\ 1,
nozzle changer K21 mean work area BB 2 right gantry 3 at HS5
X
\Pipettenwechsler_K22\ 1,
nozzle changer K22 mean work area BB 2 right gantry 2 at HS5
X
\Koplanaritaet_K21\ 0,
coplanarity K21 mean work area BB 2 right gantry 3 at HS5X
\Koplanaritaet_K22\ 0,
coplanarity K22 mean work area BB 2 right gantry 2 at HS5X
\Whispering\ 0,
Whispering down the Line 0 mean OFF/ 1 mean Wisphering ON / 2 mean
Wispering with PCB-fiducials
\be_sensor11\ 1,
comp.- sensor 11 mean gantry 1 S25HMX | P4 HS5
X
\be_sensor12\ 1,
comp.- sensor 12 mean gantry 1 S25HMX | P1 HS5
X
\be_sensor21\ 1,
comp.- sensor 21 mean gantry 3 HS5X
\be_sensor22\ 1,
comp.- sensor 22 mean gantry 2 HS5X
\Trans_Freiraum_T1\ 1,
free space under transport 1
\Trans_Freiraum_T2\ 1,
free space transport 2
\Trans_Modus_T1\ 0,
Transport mode 1 0 mean standard length; 1= long; 2 = extra long
\Trans_Modus_T2\ 0,
Transport mode 2 0 mean standard length; 1= long; 2 = extra long
\Barcode_Lesegeraet\ 0,
component Barcode reader
\BE_Hoehe\ 0
component height 0 mean standard height | 1 mean 17mm only F-ma
|
\Kameradaten\
Real configuration of cameras for this machine type (S25HM). Data set for
HS 50 have 8 camera data lines and use different ident numbers.
\Sensorsystem-ID\ 10005
PCB-camera ident number gantry 1
]
Data seperator Data Line
\Sensorsystem-ID\ 20005
PCB-camera ident number gantry
2
]
\Sensorsystem-ID\ 30005
PCB-camera ident number gantry
3
]
\Sensorsystem-ID\ 40005
PCB-camera ident number gantry
4
]
\Sensorsystem-ID\ 10014
comp-camera ident number gantry 1
]
\Sensorsystem-ID\ 20014
comp.-camera ident number gantry
2
]
\Sensorsystem-ID\ 30014
comp-camera ident number gantry
3
]
\Sensorsystem-ID\ 40014
comp-camera ident number gantry
4
|
\Kopfdaten\
real placement head configuration data set of this machine type (S25HM | a
HS 50 have 4 data sets). First for gantry 1 ...
\Kopf-Typ\ 5,
head -type (5 is 12nozzle C&P / 6 = 6nozzle C&P placement head)
\Kopfhoehe\ -22300,
head heigh
t
Edition 1.0 1 ideal_HS_503_e.xls ideal_HS SD EA 1 S GC Training
\Max_Beschl_X \ 4900,
Maximum acceleration X axis
\Max_Beschl_Y \ 3300,
Maximum acceleration Y axis
\Max_Beschl_Z_nach_oben \ 11250,
Maximum acceleration Z axis downwards
\Max_Beschl_Z_nach_unten\ 11250,
Maximum acceleration Z axis upwards
\Max_Beschl_D \ 5750,
Maximum acceleration DP- axi
s
\Max_Beschl_S \ 1100
Maximum acceleration Star- axis
]
\Kopf-Typ\ 5,
...than for gantry 2 ....
\Kopfhoehe\ -22300,
\Max_Beschl_X \ 4900,
\Max_Beschl_Y \ 3300,
\Max_Beschl_Z_nach_oben \ 11250,
\Max_Beschl_Z_nach_unten\ 11250,
\Max_Beschl_D \ 5750,
\Max_Beschl_S \ 1100
]
\Kopf-Typ\ 5,
...than for gantry 3 ....
\Kopfhoehe\ -22300,
\Max_Beschl_X \ 4900,
\Max_Beschl_Y \ 3300,
\Max_Beschl_Z_nach_oben \ 11250,
\Max_Beschl_Z_nach_unten\ 11250,
\Max_Beschl_D \ 5750,
\Max_Beschl_S \ 1100
]
\Kopf-Typ\ 5,
...and for gantry 4.
\Kopfhoehe\ -22300,
\Max_Beschl_X \ 4900,
\Max_Beschl_Y \ 3300,
\Max_Beschl_Z_nach_oben \ 11250,
\Max_Beschl_Z_nach_unten\ 11250,
\Max_Beschl_D \ 5750,
\Max_Beschl_S \ 1100
|
data seperator Data Bloc
\Maschinenpositionen\
machine position
s
\Warteposition-Portal1-(HS50=4)X\ 700000,
Warting position X gantry1 in BB1 (HS50 is 4)
\Warteposition-Portal1-(HS50=4)Y\ 1570000,
Warting position Y gantry1 in BB1 (HS50 is 4)
\Warteposition-Portal2-(HS50=1)X\ 700000,
Warting position X gantry2 in BB1 (HS50 is 1)
\Warteposition-Portal2-(HS50=1)Y\ 330000,
Warting position Y gantry2 in BB1 (HS50 is 1)
\Bestueck-Nest-X\ 788000,
PCB-reference corner (working area BB 1) X-coordinat
e
\Bestueck-Nest-Y\ 722000,
PCB-reference corner (working area BB 1) Y-coordinat
e
\Warteposition-Portal3-(HS50=3)X\ 1300000,
Warting position gantry 3 reserved for HS5X X
\Warteposition-Portal3-(HS50=3)Y\ 1570000,
Warting position gantry 3 reserved for HS5X Y
\Warteposition-Portal4-(HS50=2)X\ 1300000,
Warting position gantry 4 reserved for HS5X X
\Warteposition-Portal4-(HS50=2)Y\ 330000,
Warting position gantry 4 reserved for HS5X Y
\Bestueck-Nest-2-X\ 1623000,
PCB-reference corner (working area BB 2) X-coordinat
e
\Bestueck-Nest-2-Y\ 722000,
PCB-reference corner (working area BB 2) Y-coordinat
e
\Delta_Stopper_BB1T1_x\ 0,
position difference X for Stopper Transport 1 BB1 always 0
\Delta_Stopper_BB1T2_x\ 0,
position difference X for Stopper Transport 2 BB1 always 0
\Delta_Stopper_BB2T1_x\ 0,
position difference X for Stopper Transport 1 BB2 (long board option)
\Delta_Stopper_BB2T2_x\ 0
position difference X for Stopper Transport 2 BB2
|
data seperator Data Bloc
\Pipettenarten\
all type of nozzles for this machine at this SW
\Pipettenart\ 901,
nozzle code X0X mean ceramic nozzle
s
\Pipettenlaenge\ 16000,
nozzle length over all in µm
\Max_Vak_Wert_Offen\ 10000,
Max. vacuum value closed (theoretical max. vacuum) in 1/10 mbar
\Min_Vak_Abst\ 550,
Minimum vacuum distance open / closed nozzle in 1/10 mba
r
\Kub_Vak_Schwellwert\ 6000,
(cubic vacuum threshold) NOT anymore used
!
\Nkub_Vak_Schwellwert\ 2000,
NON cubic vacuum threshold of this nozzle type in % of the measured
vacuum distance
\Zul_Undichtigkeit\ 7000,
NOT use
d
\Zul_Verschmutzung\ 2000,
NOT use
d
\Pipetten_Messprofil\ 1
To measure in comp.-sensor (0 not to measure at comp. sensor)!!!!
precondition: with standard sleeves. New in 503
]
Data seperator of the identical data blocs
\Pipettenart\ 902,
0201 nozzle (round contact surface to component
)
\Pipettenlaenge\ 16500,
\Max_Vak_Wert_Offen\ 10000,
Edition 1.0 2 ideal_HS_503_e.xls ideal_HS SD EA 1 S GC Training