HS50_advance_level 1_20200522_221201 (1) - 第369页

1 - 4 Conte nts Student Guide HS-50 Advance d I 06/2002 Edition 4

100%1 / 567
Page
Contents 0
Student Guide HS-50 Advanced I Contents
06/2002 Edition
3
10 Component Changeover Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
10.1 Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
10.2 Component changeover tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
10.2.1 Safety instructions for docking and undocking the component changeover table. . . 7
10.2.2 Undocking the component changeover table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
10.2.3 Docking the component changeover table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
10.3 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
10.4 Overview of Mechanical Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
10.5 Resolving Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
10.5.1 Preparatory Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
10.5.2 Exchanging the Bellows Cylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
10.5.3 Exchanging Fixed Castor and/or Guide Castor. . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
10.5.4 Exchanging the "Cable/Component Table" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
10.5.5 Exchanging the Communications Unit / Exchanging the Edge Guard if
Necessary 20
10.5.6 Final Steps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
10.6 CAN - Bus Coppler Component Table Jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
1 - 4
Contents Student Guide HS-50 Advanced I
06/2002 Edition
4
Student Guide HS-50 Advanced I Edition 06/2002
10 Component Changeover Table
5
10 Component Changeover Table
10.1 Safety Instructions
WARNING 10
The "Safety Instructions" in Chapter 1 of the SIPLACE HS-50 Service Manual and User Man-
ual take precedence over these instructions.
Parts of your body may be pinched, crushed or severed by the component changeover table if:
- the handle is operated incorrectly (always use two hands!),
- the height is incorrectly set (setting for SMEMA’s height: see "Retrofit Instructions"),
- a feeder module tips over or falls,
- the component changeover table which has been moved out of the machine tips over.
No substantial lateral force is to be exerted on the component changeover table after it has been
disassembled (danger that it might tip over), therefore:
- Do not lean against it and do not brace any items against it.
- Place the component changeover table on a horizontal surface and secure it to prevent it from
starting to roll away all by itself.
Once the component changeover table has been moved out of the machine, NEVER plug it into
the machine base (= not use as intended = DANGER!).
Moving the component changeover table out of the machine leaves the cutter (etc.) accessible:
This increases the risk of injury on the cutters movable or stationary blades even while the
machine is switched off.
NEVER reach into the cutter from below or into the empty-tape duct from above, not even to
resolve a problem (e.g., jammed tape) involving the disassembly of the component changeover
table.
The component changeover table must be placed on its side when dismantling the fixed castors
/ steering castor.
Two persons are required for this procedure.
(continued on next page)
DANGER text, continued