Editi on 06/2002 S tudent Guide HS - 50 Advance d I 10 C omponent Change over T able 6 As a fundam ental rule, th e SITES T program is to be started o nly by per sonne l who h av e been trained in its use b y Siemens and…

Student Guide HS-50 Advanced I Edition 06/2002
10 Component Changeover Table
5
10 Component Changeover Table
10.1 Safety Instructions
WARNING 10
The "Safety Instructions" in Chapter 1 of the SIPLACE HS-50 Service Manual and User Man-
ual take precedence over these instructions.
Parts of your body may be pinched, crushed or severed by the component changeover table if:
- the handle is operated incorrectly (always use two hands!),
- the height is incorrectly set (setting for SMEMA’s height: see "Retrofit Instructions"),
- a feeder module tips over or falls,
- the component changeover table which has been moved out of the machine tips over.
No substantial lateral force is to be exerted on the component changeover table after it has been
disassembled (danger that it might tip over), therefore:
- Do not lean against it and do not brace any items against it.
- Place the component changeover table on a horizontal surface and secure it to prevent it from
starting to roll away all by itself.
Once the component changeover table has been moved out of the machine, NEVER plug it into
the machine base (= not use as intended = DANGER!).
Moving the component changeover table out of the machine leaves the cutter (etc.) accessible:
This increases the risk of injury on the cutter’s movable or stationary blades even while the
machine is switched off.
NEVER reach into the cutter from below or into the empty-tape duct from above, not even to
resolve a problem (e.g., jammed tape) involving the disassembly of the component changeover
table.
The component changeover table must be placed on its side when dismantling the fixed castors
/ steering castor.
Two persons are required for this procedure.
(continued on next page)
DANGER text, continued

Edition 06/2002 Student Guide HS-50 Advanced I
10 Component Changeover Table
6
As a fundamental rule, the SITEST program is to be started only by personnel who have been
trained in its use by Siemens and are therefore authorized to do so.
The cutter must also be completely assembled for the work with the SITEST program. The
changeover table must be moved into the machine and correctly connected.
The component changeover table which has been moved into the machine must always be
completely equipped with feeder modules or dummy modules (see Service Manual and User
Manual, Chapter 1, "Safety" -> "DANGER"). 10
10

Student Guide HS-50 Advanced I Edition 06/2002
10 Component Changeover Table
7
10.2 Component changeover tables
10.2.1 Safety instructions for docking and undocking the component changeover
table
WARNING 10
à Never reach into the gaps between the component changeover table and the placement sys-
tem frame while the machine is running (item 1 in Fig. 10.2 - 1
).
à Always check that the component changeover table is docked on the placement system before
connecting or disconnecting the power cable for the component changeover table at the socket
on the placement system (item 2 in Fig. 10.2 - 1
).
à NEVER connect the connecting cable for the component changeover table to the socket on the
placement system and then operate the component table outside the machine via the com-
pressed air control unit (item 3 in Fig. 10.2 - 1).
10
Fig. 10.2 - 1 Safety instructions for the component changeover table