a Use a lint-free cloth sprayed with WD 40 to protect the feeder area.
s Use a vacuum cleaner to remove any loose components from the tape container, and remove
any adhesive labels and tapes that are no longer needed.
d Cut the protruding used tape off flush with the feeder and empty the component drawer on
8mm S feeders.
: Place the feeder on the feeder area once more.
Make sure that the conveyor is in the right location and is connected correctly.
12
: Close the protective cover.
: Switch the placement system on at the main switch.
: Repeat these tasks in every feeder area.
06/2002 Edition Student Guide HS-50 Advanced I
12 Preventive Maintenance
40
12.9 Maintenance work every 4 months
Structure of the 12 segment collect&place head / DLM1
Abb. 12.9 - 1 Structure of the 12-segment collect&place head / DLM1
12
(1) Star with 12 sleeves (2) Motor for "Reject" valve adjustment drive
(3) Turning station (4) Component vision module
(5) Z-axis drive (6) Star motor