06/2002 Edition Student Guide HS-50 Advanced I
20 Appendix
8
20.3.5 Feeder Location Test Unit
20
fig 20.3 - 7 Feeder location test unit
Application: 20
The feeder location test unit is used to check the connections of the feeders on the communication
unit of the component table. 20
Student Guide HS-50 Advanced I 06/2002 Edition
20 Appendix
9
20.3.6 Power Supply for Mounting of the Star.
20
fig 20.3 - 8 Power supply calibration tool for mounting the star on the DLM1 C&P head
Application: 20
The power supply is used as a calibration tool for mounting the star. 20
06/2002 Edition Student Guide HS-50 Advanced I
20 Appendix
10
20.3.7 Calibration Tool for the Collect & Place Head
20
fig 20.3 - 9 Calibration tool for the Collect & Place Head 10.000, item number: 00327005-01
20
Gauge for the star, item no: 00326164-01
Parallel pin 1.4 mm, item no: 00326160-01
Parallel pin 1.5 mm, item no: 00326161-01
Parallel pin 1.6 mm, item no: 00326162-01
Parallel pin 1.3 mm item no: 00326163-01
Distance gauge, item no: 00325445-01
Measuring tools Usage
Gauge for the star Adjustment of zero point correction star
Parallel pin 1.4 mm
Adjustment of distance between read head of dp - station to glass
pane of sleeve
Parallel pin 1.5 mm
Parallel pin 1.6 mm
Parallel pin 1.3 mm Adjustment of distance light barrier z-axis bottom to sleeve
Distance gauge Adjustment of the distance between valve plunge and star