HS50_advance_level 1_20200522_221201 (1) - 第72页
1 - 4 Conte nts Studen t Guide HS-50 A d vance d I 06/200 2 Edition 4

Page
Contents 0
Student Guide HS-50 Advanced I Contents
06/2002 Edition
3
3 Machine Reference Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1 Reference sequence in general . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2 Preparational steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3 Initialization of the valve drives in pick up / placement and reject position . . . . . . . . . . . . . . . . 6
3.4 Initialization of the swivel in / out drive of the DP_Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.5 Preparing Z-axis reference run. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.6 Initialization (reference run) of the star axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.7 Completion of the Z axis reference run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.8 Initialization (reference run) of the DP-axis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.9 X- and Y- Commutation position search . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.10 Initialization (reference run) of X- and Y- axis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.11 Vacuum check and all nozzle turned to 0° . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.12 Hight reference run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

1 - 4
Contents Student Guide HS-50 Advanced I
06/2002 Edition
4

Student Guide HS-50 Advanced I 06/2002 Edition
3 Machine Reference Run
5
3 Machine Reference Run
3.1 Reference sequence in general
Fig. 3.1 - 1 Reference sequence in general
3.2 Preparational steps
Fig. 3.2 - 1 Preparational steps
50
W
50
W
LC
SC
Next Stations
MC
SIPLACE-LAN
Ø
Durin
g
the boot sequence the station sends the first command to the LC, called
S
tation Alife (SALF) command.
Ø
The response of the LC is with LC Alife (LALF) command. It follows with the Load machine
d
ata (LMAD). The data transfer is finished with Load end machine data (LEMA).
Ø
With the start signal the power supply is switched on.
Ø
Pressing the start button starts the reference run.