00900170-01_ID_OIS_SIS_16.0_R18-2_EN_DE - 第71页
ASM OIS/SIS Datab ases 16.0 (R18 -2) / Interf ace Description 11/2018 Edition 71 34404 Fatal error on a segment 34428 Cannot create dip job 34429 Component combination is not allowed due to size restrictions 34430 Nozzle…

ASM OIS/SIS Databases 16.0 (R18-2) / Interface Description 11/2018 Edition
70
33345
Measured blob area outside tolerance
33346
Position cannot be determined
33347
Component inspection failed
33348
Size check failed
33350
Flipped component detected
33351
Quality is too low for optical centering
33352
No component in front of the camera or component not bright enough
33354
Measured size outside tolerance
33355
Measured size in X outside tolerance
33356
Measured size in Y outside tolerance
33357
Measured structure size outside tolerance
33358
Position (approximate) cannot be determined
33359
Angle (approximate) cannot be determined
33360
Position (fine) cannot be determined
33361
Not all features of the component were detected
33362
Not all ball features of the component were detected
33363
Features outside positional tolerance
33364
Ball features outside positional tolerance
33365
Nozzle dirty
33366
Nozzle duct blocked
33367
Nozzle worn
33370
Component picked up at wrong angle
33371
Measurement with 3D sensor failed
33372
Measurement with 3D sensor: Not all connections were found
33373
Measurement with 3D sensor: At least one connection is damaged
33374
Measurement with 3D sensor: Coplanarity outside tolerance
33375
Measurement with 3D sensor: Distance between component and sensor too
small
33376
Measurement with 3D sensor: Distance between component and sensor too
great
33377
Measurement with 3D sensor: Component tilted too much
33380
Lead length inspection failed
33381
Measured lead length outside of tolerance
33382
Colinearity check: Lead positions outside of tolerance
33383
Measured lead width outside of tolerance
33387
Coarse position cannot be determined
33398
Glue dot inspection was unsuccessful
33399
Glue dot not within the target region
34403
Placement stopped

ASM OIS/SIS Databases 16.0 (R18-2) / Interface Description 11/2018 Edition
71
34404
Fatal error on a segment
34428
Cannot create dip job
34429
Component combination is not allowed due to size restrictions
34430
Nozzle combination is not allowed due to size restrictions
34432
Fatal error, maximum number of retries reached
34433
Fatal error, maximum number of retries reached
34439
Component present before pick up
34440
Component not present after pickup
34441
Component too small after pickup
34442
Component too large after pickup
34443
Component cannot be picked up
34450
No component available for placement
34451
Component too small before placement
34452
Component too large before placement
34453
Nozzle not empty after placement
34456
Component cannot be placed
34460
Component cannot be measured
34468
Cannot recycle component
34469
Cannot recycle component
34470
Cannot recycle component
34474
A nozzle change is needed, but not permitted during production. Too
many segments are disabled
34475
Failed to create job for returning nozzle
34476
Failed to create job for picking up nozzle
34477
Failed to create job for centering nozzle
34479
Cannot dip component
34480
Cannot calibrate nozzle changer
34481
Pickup position cannot be reached
34482
Placement position cannot be reached
34483
Dip position cannot be reached
34496
Glue cannot be applied to the component
34499
Component sensor covered before pickup
34602
Cannot address carrier
34603
Cannot address magazine
34810
Cannot pick up component
34902
An error occurred when picking up a component
34903
Division deactivated after component pickup errors
34915
Division not available. Reel has been removed
34920
X feeder: Error on removing foil

ASM OIS/SIS Databases 16.0 (R18-2) / Interface Description 11/2018 Edition
72
34921
X-Feeder: Input voltage too low
34922
X feeder: Component was not moved to target position within time limit
34924
X feeder: Foil torn
34925
X-Feeder: Tape drive error
34926
X feeder: Foil removal device blocked
34927
X-Feeder: Removal handle not latched
34930
X-Feeder: Reference run error
34933
X-Feeder: Error saving EEPROM
34935
X-Feeder: Splice sensor failure
36165
Dip module: Medium empty
Table 8-2: OIS relevant machine error messages