3OM-1751-002w_G5S.pdf - 第62页
3OM-1751 1-8 1303-001 3.1 Head Unit 3.1.1 Attached Head Judgment Window This window is displayed when the head option is not the same as one set as the head to be attached when the machine is started up. F3A7 [1] Set The…

3OM-1751
1-71303-001
3.1 Head Unit
When the head unit button is pressed, the following window appears.
[1]
F3A6
[1] Unit select
[High V10] Button
: When pressed, the high-speed head is selected.
[Multi] Button
: When pressed, the multi-functional head is selected.
Graphic
Development
3.1 Head Unit

3OM-1751
1-81303-001
3.1 Head Unit
3.1.1 Attached Head Judgment Window
This window is displayed when the head option is not the same as one set as the
head to be attached when the machine is started up.
F3A7
[1] Set
The head set in the machine is displayed in this data box.
In the case that the set head is "V10" head, "High-Speed V10" is displayed.
[2] Attached
The head attached to the machine is displayed in this data box.
In the case that the attached head is "V10" head, "High-Speed V10" is
displayed.
[3]
When the set head is not the same as the attached head, press this button to
re-start the system.
[4]
When the set head is the same as the attached head, press this button to
shutdown the system. Then, check the dip switch on the PCB mounted on the
head.
Note
In the case that this error occurs again, even when the dip switch is
checked, it might be caused by the communication system error.

3OM-1751
1-9
3.2 Nozzle Stocker
When the nozzle stocker button is pressed, the following window appears.
[1]
[2]
F3A8
[1] Unit select
[Non] Button
: When pressed, the unit without nozzle stocker is selected.
[High] Button
: When pressed, the unit with high-speed nozzle stocker is
selected.
[Odd] Button
: When pressed, the unit with middle size and odd shape
nozzle stocker (option) is selected.
[Multi] Button
: When pressed, the unit with multi-functional nozzle stocker
(option) is selected.
Graphic
Development
1303-001
3.2 Nozzle Stocker