3OM-1751 1-12 [3] T each [T raverse Axis Draw] Button Using this button, the traverse drawing operation offset teaching for each machine is performed by teaching the mark position located on the traverse chuck claw secti…

100%1 / 268
3OM-1751
1-11
3.3 Feeder Unit
When the feeder unit button is pressed, the following window appears.
[1]
[2]
[3]
F3A11
[1] Unit select
[Feeder] Button
: When pressed, the unit with feeder is selected.
[Tray JEDEC] Button
: When pressed, the JEDEC size tray feeder
(option) is selected.
[Tray Full Size] Button
: When pressed, the FULL size tray feeder (option)
is selected.
[2] Change Order Guidance
When one of these buttons is pressed, the attachment or removal window for
the "Tray JEDEC" (Option) or "Tray Full-Size" (Option) appears.
"Change Order Guidance" window F3A12
1303-001
Graphic
Development
3.3 Feeder Unit
3OM-1751
1-12
[3] Teach
[Traverse Axis Draw] Button
Using this button, the traverse drawing operation offset teaching for each
machine is performed by teaching the mark position located on the traverse
chuck claw section.
Note
For this operation, the traverse drawing teaching pin is required separately.
[Tray Transfer Tch] Button
Using this button, the tray pallet delivery teaching is performed.
After attaching the multi-layer tray feeder to the main machine, select the
delivery teaching.
If this teaching operation is not performed, the pallet will not be delivered
correctly to the traverse cart.
Reference
Refer to "Chapter 3: Maintenance Menu" in Volume 7 for details.
1303-001
3.3 Feeder Unit
3OM-1751
1-131303-001
4. "Unit Adj." Submenu
[1]
F3A13
[1] "Unit Adj." submenu
The following buttons are arranged on this submenu bar and can be used
to display the operation windows for execution of each unit adjustment
function.
Function Selection Buttons Description
Noz Chng.
When pressed, this button opens the "NOZ. CHNG." window,
enabling you to manually perform a cycle of the vacuum nozzle
attachment and storage operation.
Line Meas
When pressed, this button opens the "LINE MEAS" window, enabling
you to view and record the changes in E/NR traces (expressed by a
chart or using numerical values) of the linear measure sensors on each
placement head. "E/NR" stands for "Light Emitted and Not Received".
Tray
This button is used when the tray feeder (option) is to be adjusted.
Cnvr.
This button is used for the adjustment operation for the conveyor
width overall setup or manual setup.
T3A1
Graphic
Development
4. "Unit Adj." Submenu