3OM-1751 1-15 1303-001 [4] "Control Switch" Group Box The following operation buttons are arranged. When the [START] button on the operation panel is pressed in 10 seconds after the each operation button, the s…

3OM-1751
1-141303-001
4.1 "NOZ. CHNG." Window
The nozzle attachment and housing can be performed manually.
[1] [2] [4]
[5]
[3]
F3A14
[1] Head Sel
When a button is pressed, the corresponding head is selected as an object one
for nozzle change operation.
[2] Nozzle Allocation No. Selection Buttons
When a button is pressed, the corresponding nozzle to be changed is selected.
The background color of the button turns light blue.
ID of Attached Vacuum Nozzle
Nozzle Stocker Address
(Home Address for Attached Nozzle)
Notice
No nozzles can be allocated to both sides of the middle-size odd
shaped nozzle if attached.
Note
The indications in the window vary depending on the selected head.
[3] Status Indication
Displayed is the condition of the currently selected head.
Graphic
Development
4.1 "NOZ. CHNG." Window

3OM-1751
1-151303-001
[4] "Control Switch" Group Box
The following operation buttons are arranged.
When the [START] button on the operation panel is pressed in 10 seconds
after the each operation button, the selected action takes place.
[Reset Nozzle] Button
When selected, this button stores the specied nozzle in the nozzle
stocker.
When this button is pressed, the background color turns green, indicating
that the head selection button is set active.
[Set Nozzle] Button
When selected, this button picks up the selected nozzle from the nozzle
stocker and attaches it to the specied nozzle No. position.
When this button is pressed, the background color turns green, indicating
that the head and nozzle (nozzle stocker) selection buttons are set active.
[5] Nozzle Stocker tab
Using this tab, the nozzle stocker to be opened or closed and the nozzle
housed in the nozzle stocker, are designated.
Selecting the nozzle stocker using the nozzle stocker select tab and pressing
the button for an appropriate nozzle, designates the nozzle to be used.
Note
For the stocker for which the skip has been set, a message is displayed and
the stocker can not be operated.
4.1 "NOZ. CHNG." Window

3OM-1751
1-161303-001
•
Procedure for Nozzle Storage
Notice
(a) When the high-speed nozzle are used together with the middle-size
odd shaped nozzle, the middle-size odd shaped nozzle must be
stored prior to the others.
When the machine starts to store the high-speed nozzle prior to
the middle-size odd shaped nozzle, a dialog box opens, prompting
that the middle-size odd shaped nozzle must be stored rst and
indicating that the high-speed nozzle cannot be stored.
(b) Do not house the nozzle while the head picks up a component.
Doing so breaks the vacuum and the component drops.
Procedure
(1) Press the head (one of the head selection buttons) holding the nozzle desired
to be stored.
(The background color of the selected button turns light blue.)
(2) Select the nozzle (one of the nozzle allocation No. selection buttons) holding
the nozzle desired to be stored.
(The background color of the selected button turns light blue.)
(3) To select a nozzle stocker different from the original one, press the nozzle
selection button (destination address).
(4) Press the [Reset Nozzle] button.
(The background color of the button turns green and the selected head
selection button, nozzle allocation No. button, and nozzle selection button
are set active.)
(5) Press the [START] button on the operation panel.
(The selected nozzle will be housed in the nozzle stocker with the selected
address.)
4.1 "NOZ. CHNG." Window