3OM-1751 1-16 1303-001 • Procedure for Nozzle Storage Notice (a) When the high-speed nozzle are used together with the middle-size odd shaped nozzle, the middle-size odd shaped nozzle must be stored prior to the others. …

3OM-1751
1-151303-001
[4] "Control Switch" Group Box
The following operation buttons are arranged.
When the [START] button on the operation panel is pressed in 10 seconds
after the each operation button, the selected action takes place.
[Reset Nozzle] Button
When selected, this button stores the specied nozzle in the nozzle
stocker.
When this button is pressed, the background color turns green, indicating
that the head selection button is set active.
[Set Nozzle] Button
When selected, this button picks up the selected nozzle from the nozzle
stocker and attaches it to the specied nozzle No. position.
When this button is pressed, the background color turns green, indicating
that the head and nozzle (nozzle stocker) selection buttons are set active.
[5] Nozzle Stocker tab
Using this tab, the nozzle stocker to be opened or closed and the nozzle
housed in the nozzle stocker, are designated.
Selecting the nozzle stocker using the nozzle stocker select tab and pressing
the button for an appropriate nozzle, designates the nozzle to be used.
Note
For the stocker for which the skip has been set, a message is displayed and
the stocker can not be operated.
4.1 "NOZ. CHNG." Window

3OM-1751
1-161303-001
•
Procedure for Nozzle Storage
Notice
(a) When the high-speed nozzle are used together with the middle-size
odd shaped nozzle, the middle-size odd shaped nozzle must be
stored prior to the others.
When the machine starts to store the high-speed nozzle prior to
the middle-size odd shaped nozzle, a dialog box opens, prompting
that the middle-size odd shaped nozzle must be stored rst and
indicating that the high-speed nozzle cannot be stored.
(b) Do not house the nozzle while the head picks up a component.
Doing so breaks the vacuum and the component drops.
Procedure
(1) Press the head (one of the head selection buttons) holding the nozzle desired
to be stored.
(The background color of the selected button turns light blue.)
(2) Select the nozzle (one of the nozzle allocation No. selection buttons) holding
the nozzle desired to be stored.
(The background color of the selected button turns light blue.)
(3) To select a nozzle stocker different from the original one, press the nozzle
selection button (destination address).
(4) Press the [Reset Nozzle] button.
(The background color of the button turns green and the selected head
selection button, nozzle allocation No. button, and nozzle selection button
are set active.)
(5) Press the [START] button on the operation panel.
(The selected nozzle will be housed in the nozzle stocker with the selected
address.)
4.1 "NOZ. CHNG." Window

3OM-1751
1-171303-001
•
Procedure for Nozzle Attachment
Notice
(a) The middle-size odd shaped nozzle can be attached, leaving one
out of every two pitches empty.
(b) When the high-speed nozzle are used together with the middle-size
odd shaped nozzle, the high-speed nozzle must be attached prior to
the others.
When the machine starts to attach the middle-size odd shaped
nozzle prior to the high-speed nozzle, a dialog box opens, prompting
that the high-speed nozzle must be attached rst and indicating that
the middle-size odd shaped nozzle cannot be attached.
(c) Do not house the nozzle while the head picks up a component.
Doing so breaks the vacuum and the component drops.
Procedure
(1) Select the head (one of the head selection buttons) where the desired nozzle
should be attached.
(The background color of the selected button turns light blue.)
(2) Select the nozzle selection button where the nozzle to be attached is stored.
(The background color of the selected button turns light blue.)
(3) Select the nozzle allocation No. button to specify the position where the
nozzle should be attached.
(The background color of the selected button turns light blue.)
(4) Press the [Set Nozzle] button.
(The background color of the button turns green and the selected head
selection button, nozzle allocation No. button, and nozzle selection button
are set active.)
(5) Press the [START] button on the operation panel.
(The specied nozzle placement operation will be performed.)
Note
No nozzle can be attached to any nozzle No. position where a nozzle is already
attached.
4.1 "NOZ. CHNG." Window