3OM-1751-002w_G5S.pdf - 第81页

3OM-1751 1-27 1303-001 [3] Conveyor Setup Buttons When the target position is to be moved the conveyor width adjustment values are setup using the following buttons. [Tgt Wd] Button When this button is pressed the "…

100%1 / 268
3OM-1751
1-26
4.3.1 "Conveyor" Tab Sheet
[1]
[2]
[3]
"Conveyor" Tab Sheet F3A20
[1] Conveyor Display Section
The conveyor image is displayed in this section.
[2] Control Switch
These buttons are arranged to perform the following setup operations. When
any button is selected the background color of the selected button turns
green.
[Desig Width] Button
When each value for "Tgt Wd", "Clearance" and "Base Pos" are set and
the [START] button on the operation panel is pressed within 10 minutes
after pressing this button, the target position movement is performed.
[Zeroing] Button
When the [START] button on the operation panel is pressed, within 10
seconds after pressing this button, the conveyor zeroing operation is
performed.
[PCB posn.lct.snsr.Tch] Button
When this button is pressed, the teaching operation for the PCB
positioning detection sensor is performed based on the current conveyor
width.
Note
When there is a PCB on the conveyor, accurate teaching is not
available. Make sure that there is no PCB on the conveyor and press
this button to perform the teaching operation.
1303-001
Graphic
Development
4.3 "CONVEYOR" Window
3OM-1751
1-271303-001
[3] Conveyor Setup Buttons
When the target position is to be moved the conveyor width adjustment
values are setup using the following buttons.
[Tgt Wd] Button
When this button is pressed the "Tgt Wd" input window appears. When a
value is entered and the [SET] button is pressed the target value is setup.
[Clearance] Button
When this button is pressed the "Clearance" input window appears.
Set the data for the conveyor width to have some margin from the PCB
size set in the pattern program. The actual conveyor width is "PCB Size"
(Target Width) + "Clearance" (Recommended Value: 0.5 mm).
When a value is entered and the [SET] button is pressed the clearance
value is setup.
[Base Pos] Button
When this button is pressed the "Base Pos" input window appears. In
this window the base position adjusting data is setup. When the value is
entered and the [SET] button is pressed, the base position is setup.
·
Conveyor Width Manual Setup
When the conveyor width is to be set up, use the following procedure.
Procedure
(1) In each input window displayed by pressing the [Tgt Wd], [Clearance] and
[Base Pos] buttons for the "Conveyor" width, enter the data parameter for
each item.
(2) Within 10 seconds after pressing the [Tgt Wd] button, press the [START]
button on the operation panel.
(The conveyor width will be adjusted to ("Tgt Wd" value + "Clearance"
value). Also, the conveyor will be moved to the set base position.)
4.3 "CONVEYOR" Window
3OM-1751
1-281303-001
4.3.2 "PCB Stpr." Tab Sheet
The adjustment for each PCB stopper is performed on this tab sheet.
[1]
[2] [3]
"CONVEYOR" Window F3A21
[1] PCB Stopper Selection Buttons
Using these buttons the PCB stopper where the operation is to be performed
is selected.
[2] Control Switch
[UP] Button
When the [START] button is pressed on the operation panel within 10
seconds after this button is pressed, the selected PCB stopper is moved up.
[DOWN] Button
When the [START] button is pressed on the operation panel within 10
seconds after this button is pressed, the selected PCB stopper is moved
down.
[3] Status Display
Result
In this data box the PCB stopper operation result is displayed as "OK" or
"NG".
Mode
In this data box the PCB stopper present status is displayed as "UP" or
"Down".
Time [ms]
In this data box the PCB stopper operation time is displayed.
Graphic
Development
4.3 "CONVEYOR" Window