4.5.3 Improved Placement of Snap-In Components
The feature for placement of snap-in OSC components has been improved. With this feature, the
system can check whether the pins of such components are "snapped-in", i.e. completely inserted.
The actual Z-axis position of every snap-in placement will be compared with its corresponding
height reference value. These values must match each other. It is recommended to set support
pins close to the snap-in placement positions.
The Snap-In feature has to be selected as placement process for the component shape in the
Component Shape Editor. Then the Snap-In Check option in the Placement group has to be
enabled for the component shape in the Handling tab. Additionally, the snap-in threshold that shall
be used for comparing the two values has to be specified in mm in the Z-Threshold field.
A warning will be displayed if the snap-in check is enabled and the threshold set to 0.
If the snap-in check is enabled for a component shape, the placement force will be (re)set to 65 N.
SIPLACE Pro will force the corresponding placement positions onto stations with station software
version >= 710.
4.6 Special Fiducial Evaluation for LED Centering
Current manufacturing processes of lighting products require placement of LED components
precisely aligned relative to oblong holes or other features of the board.
For this, the new Evaluation Mode fiducial type attribute has been introduced to provide additional
information for describing such features. In the Fiducial Type Editor, the Evaluation Mode can be
selected, indicating how fiducial positions using the current fiducial type shall be evaluated by the
station software. Two evaluation modes are listed: Standard (X,Y) and Y. The list is enabled for
any fiducial of type Fiducial that has not yet been taught by SIPLACE Vision. Once the Vision data
has been taught and uploaded back, this field will be disabled. The Vision data has to be deleted
via the corresponding Desk function to enable the field again.
In the Standard (X,Y) evaluation mode, the station software will consider the X and Y data of the
fiducial position (default value, used by all "old" fiducials).
The Y evaluation mode is suitable for oblong holes or notches. The station software will only use
the measured Y data for panel correction. The X target position is only used to determine where to
position the camera and the angle describes the direction of the oblong hole / notch with respect to
the panel.
If the Y evaluation mode is selected for at least one fiducial in the recipe, a corresponding
SIPLACE LED Centering Machine Connection license is required for each machine of the line.
4.7 MES Callbacks License Check
The usage of MES callbacks in 3
rd
party applications requires the new MES - Process Interlocking -
SIPLACE - Machine Connection license. This license is bound to the machine ID and is checked by
the Line Control for each station to which the recipe shall be downloaded.
The license check is performed when the MES callback functionality is activated for a line in the
Line Control GUI under ConfigurationMES Verification as displayed in the following table.
SIPLACE Pro 14.0 (R16-2) / Version Description 12/2016 Edition
17
The license check is performed: Result if the license is missing:
When the MES callback functionality is
activated for a line with Enable Download
Verification
An error message is displayed but the MES
callback functionality is activated.
When the MES callback functionality is
activated for a line with Enable Device
triggered Recipe Verifications (DEK Printer)
An error message is displayed but the MES
callback functionality is activated.
Just before each MES callback The MES callback will not be performed and the
download will be aborted.
Just before each MES VerifyRecipe callback The MES VerifyRecipe callback will not be
performed and the recipe will not be activated
on the DEK Printer.
Table 4-1: License check for MES callbacks
4.8 Increased Number of Custom Nozzles
The number ranges for custom nozzles have been extended as follows:
Additional range 4700 4999 for 40xx nozzles of the C&P20 P placement head.
Additional range 2500 2799 for 20xx nozzles of the CPP placement head.
Additional range 2900 2999 for 28xx nozzles of the CPP placement head.
4.9 Improved Handling of High Components in Trays
An overall tray height has been introduced in SIPLACE Pro for the tray reserve type. The user can
now specify trays in which the components are located in deep pockets in the Waffle Pack Tray
Editor.
The new Overall Height attribute will be sent to stations with station software version >= 710.
4.10 Nozzle Tip Displayed At Pickup Location
The nozzle tip is now displayed as an overlay in the component shape drawing when the pickup
location is taught at the station. At download, Line Control sends additional information about the
nozzle tip to stations with station software version >= 710 for each nozzle setup on the station. The
operator can change the pickup point at the station and upload the changes into the SIPLACE Pro
database.
SIPLACE Pro 14.0 (R16-2) / Version Description 12/2016 Edition
18
4.11 Miscellaneous Features
The Heavy Board Option Line Connection floating license will not be checked any more in the
Line Control Server. This applies to all station versions.
The SIPLACE Pro for DEK printer feature is not fully supported in this SIPLACE Pro version.
The recipe download from Line Control is not yet permitted.
The BMC AppSight Windows Black Box Service recording tool is not supported anymore. The
tool itself will not be automatically deleted from existing systems. It has to be manually
uninstalled.