00197973-10_SM_MaterialTower - 第176页

Portal 00197 973 - 10 / 02 , 2016 8- 12 © ASM SIPLACE Mat. Tower St ora ge Ser vice Manu al 8.4 Reel Detecto r 8.4.1 Introducti on This modification instructi on describes how t o change the reel detection sens or on SIP…

100%1 / 274
00197973-10 / 02 , 2016 Portal
SIPLACE Mat. Tower Storage Service Manual © ASM 8-11
Step 3
Exchange the old sensor with a new one.
Step 4
Mount the sensor holder on its place and plug the electrical connectors as described in step 2 and
1.
Step 5
Plug in the power connector and switch on the machine.
Assure that noone is manipulating the software whilst you are inside the machine.
Step 6
Setup the position of the sensor that following
conditions are fulfilled:
Fully open the portal door. The red LED must be
on, meaning the sensor is activated.
Fully close the portal door. The red LED must be
of, meaning the senso
r is deactivated.
Step 7
Remove all tools and close the doors of the machine.
Connect the compressed air supply.
Initialize the machine by means of the software.
Portal 00197973-10 / 02 , 2016
8-12 © ASM SIPLACE Mat. Tower Storage Service Manual
8.4 Reel Detector
8.4.1 Introduction
This modification instruction describes how to change the reel detection sensor on SIPLACE
Material Tower.
Spare part number: 03126680-01
Before starting the maintenance, read the Safety instructions carefully.
8.4.2 Tools, Material and Scheduling
For an effective and efficient maintenance, the following resources have to be provided:
Required Tools / Auxiliary Material / Spare parts
Tools: Allen key Nr. 3 and 4
Slotted screw driver nr. 1
Side cutter
Auxiliary Material: Cable ties
Spare parts:
03126680
-01, reel detection sensor
Time needed
Schedule around 30 minutes for this task.
00197973-10 / 02 , 2016 Portal
SIPLACE Mat. Tower Storage Service Manual © ASM 8-13
8.4.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
Any work with or at the equipment must be carried out by skilled and
trained personnel in accordance with the locally applicable
regulations.
Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
NO item must be unloaded.
Machine operating
condition:
Shut down
Main electrical
power:
Equipment disconnected from power supply system. The Main Switch
(switched off) locked by means of a padlock to secure the main switch
against unintentional switching on.
Compressed air /
Nitrogen (if used):
Equipment disconnected from compressed air or nitrogen supply.
Access:
Open the maintenance door on the left side.