00197973-10_SM_MaterialTower - 第106页

Z Axis 001 97973 - 10 / 02 , 20 16 6- 24 © ASM SIPLACE Mat. Tower St ora ge Ser vice Manu al Remove cable from Y axis motor Cut off the cab le tie and re move it. Remove the c onnectors. Loosen and rem ove the shield scr…

100%1 / 274
00197973-10 / 02 , 2016 Z Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 6-23
Remove cable duct
Loosen and remove the two screws and the
cable clamping itself.
Cut off all cable ties and remove them.
Remove the defective hybrid cable.
Loosen and remove the five screws of the cable
duct (1).
Put the cable duct on the floor.
Z Axis 00197973-10 / 02 , 2016
6-24 © ASM SIPLACE Mat. Tower Storage Service Manual
Remove cable from Y axis motor
Cut off the cable tie and remove it.
Remove the connectors.
Loosen and remove the shield screw.
Slip out the cable.
00197973-10 / 02 , 2016 Z Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 6-25
Cut off and remove the cable ties (1).
Remove cable from gripper
Remove the three connectors (1).
Cut off the three cable ties and remove them (2).
Remove the connector (1).
Loosen and remove the shield screw (2)