00197973-10_SM_MaterialTower - 第115页
0019797 3 - 10 / 02 , 2016 Z Axis SIPLACE Mat. Towe r St ora ge Serv ice Manual © ASM 6- 33 Mount hybrid c able at Z m otor Bring the new hyb rid cable into c orrect position. Mount the cable c lamp, make sure the notche…

Z Axis 00197973-10 / 02 , 2016
6-32 © ASM SIPLACE Mat. Tower Storage Service Manual
Mount cable duct
Lay the hybrid cable into the cable duct,
according to the picture.
Mount the two cable clamps, make sure the
notches of the form clamping parts correspond
to the hybrid cable diameter. Do not tighten the
clamping screws.
Put up the cable duct and fix it with the two or
three upper screws (1). Do not tighten the
screws.
Manually move the gripper to the uppermost
position.
Make a loop with the cable as shown on picture
(1).
Tighten the screws of the upper cable clamp (2),
do not overtighten.
Stretch the hybrid cable in the duct very carefully.
Tighten the screws of the lower cable clamp, do not overtighten.
Screw in the remaining fixing screws of the duct and tighten all five screws.
Fix the hybrid cable along the cable duct by means of cable ties.

00197973-10 / 02 , 2016 Z Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 6-33
Mount hybrid cable at Z motor
Bring the new hybrid cable into correct position.
Mount the cable clamp, make sure the notches
of the form clamping parts correspond to the
hybrid cable diameter. Do not tighten the
clamping screws.
Check for proper cable routing illustrated on the
picture.
Tighten the screws of the cable clamping, do not
overtighten.
Tie
together the two hybrid cables by using
cable ties.
Make sure the hybrid cables do not touch the
chassis.
Mount hybrid cable along X axis
Bring the new hybrid cable into correct position
(behind the X hybrid cable).
Mount the cable clamp (1), make sure the
notches of the form clamping parts correspond
to the hybrid cable diameter. Check again for
proper cable routing and tighten the clampin
g
screws, do not overtighten.
Fix the cable by using cable ties (2).

Z Axis 00197973-10 / 02 , 2016
6-34 © ASM SIPLACE Mat. Tower Storage Service Manual
Connect hybrid cable to terminal
The following connectors have to be plug
ged in:
• Slot 1 X1
• Slot 4 X1 and X2
• Slot 5 X1
Plug in all four connectors (connectors and plug
in locations are labelled).
Re
-mount all cables of the plugged in
connectors, which are not part of the hybrid
cable (watch out for the correct pin position).
Mark the cables for easy re
-mounting after the
exchange of the hybrid cable.
Re
-mount all the power cables (48 V)
(brown/white) by means of a screwdriver (same
position as power cables of adjacent connector,
pin 22 and 24).