00197973-10_SM_MaterialTower - 第211页
0019797 3 - 10 / 02 , 2016 Structu re SIPLACE Mat. Towe r St ora ge Serv ice Manual © ASM 10 -3 Machine loading: • The sto red items in this stack mu st be unloaded i n advance. Machine operating cond ition : • Shut d o …

Structure 00197973-10 / 02 , 2016
10-2 © ASM SIPLACE Mat. Tower Storage Service Manual
Spare parts:
03126682
-01, Cell plate
including 2 knobs
Time needed
Schedule around 10 minutes for this task.
10.1.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
• Any work with or at the equipment must be carried out by skilled and
trained personnel in accordance with the locally applicable
regulations.
• Inform all involved persons regarding the currently running
maintenance works.

00197973-10 / 02 , 2016 Structure
SIPLACE Mat. Tower Storage Service Manual © ASM 10-3
Machine loading:
• The stored items in this stack must be unloaded in advance.
Machine operating
condition:
• Shut down
Main electrical
power:
• Equipment disconnected from power supply system. The Main Switch
(switched off) locked by means of a padlock to secure the main switch
against unintentional switching on.
Compressed air /
Nitrogen (if used):
• Equipment disconnected from compressed air or nitrogen supply.
Access:
• Open the door on the right side of the machine
• Remove the cover where the cell plate will be replaced
10.1.4 Exchange steps
Step 1
Remove all shelves in the cell plate that needs to
be exchanged.

Structure 00197973-10 / 02 , 2016
10-4 © ASM SIPLACE Mat. Tower Storage Service Manual
Step 2
Cover the area below the cell plate with sheets
to prevent littering SIPLACE Material Tower with
drilling splinters.
Step 3
Drill completely through both blind rivet nuts.
Afterwards, the cell plate can be removed.
At the back of the plate, the two endings of the
blind rivet nuts were cut and fell down on the
ground. Make sure both of them are removed
from