00197973-10_SM_MaterialTower - 第217页

0019797 3 - 10 / 02 , 2016 Option Air Dryer SIPLACE Mat. Towe r St ora ge Serv ice Manual © ASM 11 -3 11.1.4 Exchange steps Cover removal Remove the foll owing covers t o retrofit the air dryer: • Tall co ver left side o…

100%1 / 274
Option Air Dryer 00197973-10 / 02 , 2016
11-2 © ASM SIPLACE Mat. Tower Storage Service Manual
Spare parts:
03124552
-01, RETROFIT Air Dryer including:
Membrane dryer
Air Flow Limiter
4mm, 8mm and 15mm hose
Possibly: Connection panel (if old panel
version without holes mounted)
Through hole connectors for air
supplies/exhaustion
Magnetic valve
Control cable for magnetic valve
Drain cover
Sealing belts
Humidity sensor
Time needed
Schedule around 2 hours for this task.
11.1.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
Any work with or at the equipment must be carried out by skilled and
trained personnel in accordance with the locally applicable
regulations.
Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
NO item must be unloaded.
Machine operating
condition:
Shut down
Main electrical
power:
Equipment disconnected from power supply system. The Main Switch
(switched off) locked by means of a padlock to secure the main switch
against unintentional switching on.
Compressed air /
Nitrogen (if used):
Equipment disconnected from compressed air or nitrogen supply.
Access:
Open the left side door of the machine, where the electrical unit and
the air dryer is located.
00197973-10 / 02 , 2016 Option Air Dryer
SIPLACE Mat. Tower Storage Service Manual © ASM 11-3
11.1.4 Exchange steps
Cover removal
Remove the foll
owing covers to retrofit the air
dryer:
Tall cover left side of the portal
Small cover below the portal
Open both maintenance doors
Step 1
Position of the connection plate is below the
portal.
It might be required to remove the few lower
shelves to gain comfortable access to the plate.
Option Air Dryer 00197973-10 / 02 , 2016
11-4 © ASM SIPLACE Mat. Tower Storage Service Manual
NT-1004898, 8mm bulkhead union
NT-1004897, 4mm bulkhead union
69.999.00021, 15mm elbow union
69.999.00022, 15mm bulkhead union
40.050.06725, silencer
Prepare the required parts. There are two
possibilities in this case:
If the connection plate on this storage unit is
a new one, all parts will be loose.
If the new connection plate is in the
delivery, all parts are already mounted and
the following intermediate steps can be
skipped
. Just replace the new plate with the
old one and go to step 2.
Wrap Teflon tape around the thread of the
15mm bulkhead union (approx. 5 times).
Remove all three caps covering the holes by
pressing them through.