Option Air Dryer 0019797 3 - 10 / 02 , 2016 11 - 10 © ASM SIPL ACE Mat. Tower S tor age Service M anua l Step 9 The 4mm hose must make a curve behind the electri c plate. Fit it properly usi ng a cable tie holder at the …

00197973-10 / 02 , 2016 Option Air Dryer
SIPLACE Mat. Tower Storage Service Manual © ASM 11-9
Step 8
Lead the hoses up at the side of the electric
plate. Use the existing holes to place cable tie
holders.

Option Air Dryer 00197973-10 / 02 , 2016
11-10 © ASM SIPLACE Mat. Tower Storage Service Manual
Step 9
The 4mm hose must make a curve behind the
electric plate. Fit it properly using a cable tie
holder at the existing
hole.
Afterwards the hose has to be passed through
the hole in the drain cover above.
Step 10
Cut and connect the hoses as shown on picture.

00197973-10 / 02 , 2016 Option Air Dryer
SIPLACE Mat. Tower Storage Service Manual © ASM 11-11
Step 11
Fit the connection hose 8mm between the
magnetic valve and the air dryer.
Step 12
Connect the cable at the magnetic valve (colour
not important).
Fit the cable all the way down to the Indel COP.
Change the side at the beginnin
g of the
electronic plate as shown on the picture.
Indel COP connection:
• White: Slot 1, X2, 9
• Brown: Slot 1, X2, 8