00197973-10_SM_MaterialTower - 第228页

Option Air Dryer 0019797 3 - 10 / 02 , 2016 11 - 14 © ASM SIPLACE Mat. Tower St ora ge Serv ice Manu al Step 15 Remov e all tools and close the doo rs of the machine . Plug in the p ower connector, connect the compressed…

100%1 / 274
00197973-10 / 02 , 2016 Option Air Dryer
SIPLACE Mat. Tower Storage Service Manual © ASM 11-13
Fit the clamping section in all 8 edges of the
doorway.
ATTENTION:
On the lower and upper side has to
be a free distance of around 20 mm allowing the
door to close properly!
Step 14 Humidity sensor
CAUTION : Do not touch the humidity sensor
with bare fingers! Use a thin cloth.
Carefully take the humidity sensor out of the
packing.
Push the sensor in the correct slot with the
mirror plate looking down.
It might be helpful to bend the outer legs wi
th a
small pincer.
Option Air Dryer 00197973-10 / 02 , 2016
11-14 © ASM SIPLACE Mat. Tower Storage Service Manual
Step 15
Remove all tools and close the doors of the machine.
Plug in the power connector, connect the compressed air supply and switch on the machine.
Initialize the machine by means of the software.
Step 16
On the page
System - Storage Devices/Units,
load t
he according storage unit.
Press
Edit
Activate the two boxes for
Temperature/Humidity Monitoring
and Air
dryer
.
Re
-initialise the storage unit.
11.2 Substitute Magnetic Valve
11.2.1 Introduction
This modification instruction describes how to substitute the SMC magnetic valve VX250HY of the
Air Dryer Option on SIPLACE Material Tower with the valve VP342K.
Spare part number: 03124531-01
Before starting the maintenance, read the Safety instructions carefully.
11.2.2 Tools, Material and Scheduling
For an effective and efficient maintenance, the following resources have to be provided:
Required Tools / Auxiliary Material / Spare parts
Tools: Allen key nr. 2.5
Auxiliary Material: none
00197973-10 / 02 , 2016 Option Air Dryer
SIPLACE Mat. Tower Storage Service Manual © ASM 11-15
Spare parts:
03124531
-01, Sol valve kit for TH option
Time needed
Schedule around 10 minutes for this task.
11.2.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
Any work with or at the equipment must be carried out by skilled
and trained personnel in accordance with the locally applicable
regulations.
Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
NO item must be unloaded.
Machine operating
condition:
Shut down
Main electrical power:
The Main Switch must be switched off.
Compressed air /
Nitrogen (if used):
Equipment disconnected from compressed air or nitrogen supply.
Access:
Open the left side door of the machine, where the electrical unit and
the air dryer is located.