00197973-10_SM_MaterialTower - 第23页
00197973 - 10 / 02 , 2016 SIPLACE Mat. Tower St ora ge Ser vice Manu al © ASM 2-1 2 Gener al 2.1 Check tension of all belts 2.1.1 Introducti on This instruction describes how to check an d setup the t ension of all belts…

00197973-10 / 02 , 2016
SIPLACE Mat. Tower Storage Service Manual © ASM 2-1
2 General
2.1 Check tension of all belts
2.1.1 Introduction
This instruction describes how to check and setup the tension of all belts on SIPLACE Material
Tower.
Before starting the maintenance, read the Safety instructions carefully.
If the tension of a belt has been modifies, all stacks must be recalibrated. Therefore, SIPLACE
Material Tower must be emptied in advance by means of the software.
However, as the unloading and recalibration is time
-consuming it is recommended first to
check all tensions without modifying them. Proceed with the unloading of the stacks only if a
new setup of a belt is required.
2.1.2 Tools, Material and Scheduling
For an effective and efficient maintenance, the following resources have to be provided:
Required Tools / Auxiliary Material / Spare parts
Tools: Allen key nr. 2, 2.5, 3 and 5
Torque key nr. 3 and 5 (torque range min-max: 1 N - 10 N)
Wrench Nr. 10
Belt tension meter (frequency range min-max: 20 Hz - 450 Hz), e.g. Sonic Tension
Meter / Gates Corporation Denver, Colorado
Measuring tape 5m
Auxiliary
Material:
Loctite Threadlocker Blue 242

General 00197973-10 / 02 , 2016
2-2 © ASM SIPLACE Mat. Tower Storage Service Manual
Spare parts: none
Time needed
Schedule around 5 to 30 minutes for this task (depends on the effort to adjust tension).
2.1.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
• Any work with or at the equipment must be carried out by skilled and
trained personnel in accordance with the locally applicable
regulations.
• Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
• All stored items must be unloaded in advance.
Machine operating
condition:
• Shut down
Main electrical
power:
• Equipment disconnected from power supply system. The Main Switch
(switched off) locked by means of a padlock to secure the main switch
against unintentional switching on.
Compressed air /
Nitrogen (if used):
• Equipment disconnected from compressed air or nitrogen supply.
Access:
• Open both doors of the machine.