0019797 3 - 10 / 02 , 2016 Option Air Dryer SIPLACE Mat. Towe r St ora ge Serv ice Manual © ASM 11 - 25 Before starting the maintenance, read the Safety instructions carefully. 11.5.2 Tools, Material an d Schedulin g For…

100%1 / 274
Option Air Dryer 00197973-10 / 02 , 2016
11-24 © ASM SIPLACE Mat. Tower Storage Service Manual
Access:
Open the right side door of the machine, ir the Z axis is on this side,
push it softly back so you can step in.
11.4.4 Exchange steps
Step 1
CAUTION : Do not touch the humidity sensor
with bare fingers! Use a thin cloth.
Remove the existing sensor.
Carefully take the humidity sensor out of the
packing.
Push the sensor in the correct slot with the
mirror plate looking down.
It might be helpful to bend the outer legs with a
small pincer.
Step 2
Remove all tools and close the doors of the machine.
Plug in the power connector and switch on the machine.
Initialize the machine by means of the software.
11.5 Sealing Kit
11.5.1 Introduction
This modification instruction describes how to apply the complete sealing kit on a SIPLACE Material
Tower at customer side.
Spare part number: 03124555-01
00197973-10 / 02 , 2016 Option Air Dryer
SIPLACE Mat. Tower Storage Service Manual © ASM 11-25
Before starting the maintenance, read the Safety instructions carefully.
11.5.2 Tools, Material and Scheduling
For an effective and efficient maintenance, the following resources have to be provided:
Required Tools / Auxiliary Material / Spare parts
Tools: Allen Key Nr. 2.5
Side cutter (big and small)
Scissors
Auxiliary Material: none
Spare parts:
03124
555-01, Sealing Kit
Time needed
Schedule around 30 minutes for this task.
11.5.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
Any work with or at the equipment must be carried out by skilled and
trained personnel in accordance with the locally applicable
regulations.
Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
NO item must be unloaded.
Machine operating
condition:
Shut down
Option Air Dryer 00197973-10 / 02 , 2016
11-26 © ASM SIPLACE Mat. Tower Storage Service Manual
Main electrical
power:
Equipment disconnected from power supply system. The Main Switch
(switched off) locked by means of a padlock to secure the main switch
against unintentional switching on.
Compressed air /
Nitrogen (if used):
Does not matter.
Access:
Open both maintenance doors.
11.5.4 Exchange steps
Cover removal
Remove the following covers:
Small cover above the portal
Open both maintenance doors