Step 3
Reassemble the two body parts and screw tight.
Reattach a cable tie to fixate the drier lower part.
Push in the 4mm hose.
Step 4
Remove all tools and close the doors of the machine.
Plug in the power connector, connect the compressed air supply and switch on the machine.
Initialize the machine by means of the software.

00197973-10 / 02 , 2016
SIPLACE Mat. Tower Storage Service Manual © ASM 12-1
12 Service Door Monitoring
12.1 Retrofit Service Door Monitoring
12.1.1 Introduction
This instruction describes how to install the Service Door Monitoring on a SIPLACE Material Tower
at customer site.
Spare part number: RFNS-150196-1
Before starting the installation, read the Safety instructions carefully.

Service Door Monitoring 00197973-10 / 02 , 2016
12-2 © ASM SIPLACE Mat. Tower Storage Service Manual
12.1.2 Tools, Material and Scheduling
For an effective and efficient maintenance, the following resources have to be provided:
Required Tools / Auxiliary Material / Spare parts
Tools: Side cutter
Double ladder (small and large)
Wire stripper
Crimping pliers for end sleeves
Long-nose pliers
Set of Allen keys
Set of Phillips screwdrivers
Drilling machine
Metal drill 3 mm
Countersink (diameter max. 10 mm / 90°)
Center punch
Ruler
Pencil
Carpet knife
Vacuum cleaner
Auxiliary Material: Cable Ties
Thread-lock paint red (e.g. ZK1003 EFDEZELL-Lackfarbe)
Wire end ferrules for double wire
Spare parts:
RFNS
-150196-1