00197973-10_SM_MaterialTower - 第253页
0019797 3 - 10 / 02 , 2016 Serv ice D oor M onit oring SIPLACE Mat. Tower St ora ge Ser vice Manu a l © ASM 12 -7 Mounting Sensor an d Magnet, left si de of the machine Fix the sensor (part with the 3050 mm cable) on the…

Service Door Monitoring 00197973-10 / 02 , 2016
12-6 © ASM SIPLACE Mat. Tower Storage Service Manual
On the right side of the machine, mount an edge
protector on top between reinforcing bracket
and stack (see picture series). It is the aim to
protect the sensor cable. The blank edge of the
sheet metal would scrub
at the cable as a result
of door opening and closing and possible
vibrations.
Grasp the edge protector by means of a long
-
nose plier.
Slide the edge protector over the edge of the
sheet metal.
At the end, press the edge protector down by
using a screw
driver.
On the left side of the machine, if not already
exist, mount an edge protector on the side of
the sheet metal where the existing cables are.
Scrubbing on the left side is not that critical, but
to prevent any malfunction it is recommended
to mount
the protector.

00197973-10 / 02 , 2016 Service Door Monitoring
SIPLACE Mat. Tower Storage Service Manual © ASM 12-7
Mounting Sensor and Magnet, left side of the machine
Fix the sensor (part with the 3050 mm cable) on
the left side of the machine, on the door with
the locking mechanism.
Tighten the screws and make sure again the
screws are flush with the door surface (1).
Attach an adhesive pad (2) on top of the sensor.
Route the cable as shown on picture, fix it with a
cable tie and route it through the hole of the
door (3).
Fix the magnet (part without cable) on the
opposite door without locking mechanism.
Tighten the screws and make sure again the
screws are flush with the door surface.

Service Door Monitoring 00197973-10 / 02 , 2016
12-8 © ASM SIPLACE Mat. Tower Storage Service Manual
Mounting Sensor and Magnet, right side of the machine
Fix the sensor (part with the 4500 mm cable) on
the right side of the machine, on the door with
the locking mechanism.
Tighten the screws and make sure again the
screws a
re flush with the door surface.
Mount 2 adhesive pads (1) as shown on picture.
Route the cable as shown on picture and route it
through the hole of the door the same way as on
the left side of the machine. Fix the cable on the
pads by means of a cable ti
e.
Fix the magnet (part without cable) on the
opposite door without locking mechanism.
Tighten the screws and make sure again the
screws are flush with the door surface.