00197973-10_SM_MaterialTower - 第261页

0019797 3 - 10 / 02 , 2016 Serv ice D oor M onit oring SIPLACE Mat. Tower St ora ge Ser vice Manu a l © ASM 12 - 15

100%1 / 274
Service Door Monitoring 00197973-10 / 02 , 2016
12-14 © ASM SIPLACE Mat. Tower Storage Service Manual
Do the cabling according to the following table.
For additional information, see also the schematics. A cabling overview on the next page shall give
an idea of the whole cabling.
From To Remark
T2 all 230 V
inputs
L/N/Earth
Release the power supply from the profile rail
Remove the cable ESSW-000185 from the power supply
Remove the cable insulation for additional 70 mm
Re-insert N/Earth to the power supply
Insert L to SR1 13
SR1 14 T2 L
SR1 A1 X500 24V
X300 1
Remove cable ESSW-000187.
Crimp removed cable together with cable coming from SR1
S34.
Insert crimped end to SR1 S11
SR1 S12
Crimp cable coming from SR1 S12 together with DoorL
white.
Insert crimped end to SR1 S52
SR1 A2 X500 0V
X300 1 X400 48V
X400 48V Remove cable ESSW-000188.
Insert removed cable to X800 1.
DoorR white X800 1
DoorR brown X800 2
DoorL brown X800 2
DoorR black X800 24V
DoorL black X800 24V
X500 24V X800 24V
SR1 S22 SR1 S21 Bridge, potentially pre-wired
DoorL blue COP Slot1 X1
12
See COP overview on next page.
DoorR blue COP Slot1 X1
14
00197973-10 / 02 , 2016 Service Door Monitoring
SIPLACE Mat. Tower Storage Service Manual © ASM 12-15
Service Door Monitoring 00197973-10 / 02 , 2016
12-16 © ASM SIPLACE Mat. Tower Storage Service Manual
Routing of the Cable Excess
If cabling a SIPLACE Material Tower Regular, the
sensor cable from the right side of the machine
is too lon
g.
In this case just route it as shown on the picture.
Adjusting the Sensor
Enter the machine with a small double ladder.
Clos
e the door.
Slightly loosen the two fixing screws of the
sensor (part with the cable)
Adjust the position of the sensor. The space
between the sensor and the magnet must not
exceed 3 mm.
Make sure the doors can be opened and closed
smoothly without coll
ision of sensor and
magnet.
Do the same procedure on the other side of the
machine.