12.1.5 Initial Setup and Test
Preparation
Check again for proper cable routing.
Check on both sides of the machine the cable movement during door closing and opening.
Make sure no foreign objects are inside the machine which could cause any collision (tools / cut
cable ties etc.)
Make sure all the stored items are in their proper position (probably displaced during retrofit
mounting).
Close the service doors.
Check the version of the Material Tower software. The version must be 20.0 or higher. If existing
version is lower, install a software update.
Check Service Doors and Emergency Stop
Power up the SIPLACE Material Tower
as
described on chapter 9 in the All
-In-One manual.
Start desktop PC with Material Tower software.
Start initialization (press softkey
Initialize on
Material Tower, screen
Overview).
During initialization, open one of the doors and
the SIPLACE Material
Tower should immediately
stop running. Additionally one of the icons,
shown on the picture, should appear on the
GUIK (screen on machine).
Close the door and initialize the machine again.
Do the same procedure also for the door on the
other side of the m
achine.
Close the door and initialize the machine again.
During initialization, press the emergency stop
button on the portal and the SIPLACE Material
Tower should immediately stop running.
Additionally the icon, shown on the picture,
should appear on th
e GUIK (screen on machine).
Release the button and initialize the machine
again.
Note:
If both doors are open, both icons are shown alternately. If the emergency stop is pressed
additionally, the emergency stop icon and the door icons are shown alternately.
00197973-10 / 02 , 2016 Service Door Monitoring
SIPLACE Mat. Tower Storage Service Manual © ASM 12-19
12.1.6 Schematics
The following schematic sheets are just a selection of the complete schematics.
It is divided into two parts:
• ESSW000300 Index A: schematics of the first release (without service door monitoring)
• ESSW000300 Index B: schematics of the first release with retrofit kit Service Door Monitoring
The intention of the two parts is to have an opportunity to compare the cabling before and after
the installation of the retrofit kit.

Service Door Monitoring 00197973-10 / 02 , 2016
12-20 © ASM SIPLACE Mat. Tower Storage Service Manual
First Release Page 100 (without service door monitoring)