0019797 3 - 10 / 02 , 2016 General SIPLACE Mat. Towe r St ora ge Serv ice Manual © ASM 2- 11 Calibration In the software, in System - Sto rag e Device s/Units select the a ppropriate machine in the table and p ress Load …

General 00197973-10 / 02 , 2016
2-10 © ASM SIPLACE Mat. Tower Storage Service Manual
Loosen the l
ocking screw below the gripper.
Setup the new tension by turning the black
tensioning screw accordingly. (increase tension
by turning clockwise)
Tighten the locking screw below the gripper and
measure the tension again.
Repeat this step until the tensio
n is within the
limits.
Clear inside of the machine
Remove all tools and close the doors of the machine.
Plug in the power connector and switch on the machine.
Initialize the machine by means of the software.

00197973-10 / 02 , 2016 General
SIPLACE Mat. Tower Storage Service Manual © ASM 2-11
Calibration
In the software, in
System - Storage
Devices/Units
select the appropriate machine in
the table and press
Load.
In tab
Calibration calibrate the all axes and
follow the instructions given by the software.