00197973-10_SM_MaterialTower - 第44页

X Axis 0019797 3 - 10 / 02 , 2016 4-4 © ASM SIPLACE Mat. Tower S tor ag e Service Ma nual Auxili ary Material: none Spare parts: 03124541 - 01, X Motor Time needed Schedu le around 15 minutes fo r this task. 4.1.3 Prere …

100%1 / 274
00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-3
4.1 X Motor
4.1.1 Introduction
This modification instruction describes how to change the motor of the X Axis on SIPLACE Material
Tower.
Spare part number: 03124541-01
Before starting the maintenance, read the safety instructions carefully.
After this modification all stacks must be recalibrated. Therefore, SIPLACE Material Tower
must be emptied in advance by means of the software.
4.1.2 Tools, Material and Scheduling
For an effective and efficient maintenance, the following resources have to be provided:
Required Tools / Auxiliary Material / Spare parts
Tools: Allen key nr. 3, 4 and 5
Torque key nr. 3 and 4 (torque range min-max: 1 N - 10 N)
X Axis 00197973-10 / 02 , 2016
4-4 © ASM SIPLACE Mat. Tower Storage Service Manual
Auxiliary Material: none
Spare parts:
03124541
-01, X Motor
Time needed
Schedule around 15 minutes for this task.
4.1.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
Any work with or at the equipment must be carried out by skilled and
trained personnel in accordance with the locally applicable
regulations.
Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
All stored items must be unloaded in advance.
Machine operating
condition:
Shut down
Main electrical
power:
Equipment disconnected from power supply system. The Main Switch
(switched off) locked by means of a padlock to secure the main switch
against unintentional switching on.
Compressed air /
Nitrogen (if used):
Equipment disconnected from compressed air or nitrogen supply.
Access:
Open both maintenance doors of the machine.
00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-5
4.1.4 Exchange steps
Step 1
Loosen the rigid coupling by loosening both
screws. Move the coupling up as far as possible
and refasten the upper screw. The couplin
g
should now be fixed on the shaft.
Securely hold the shaft in one hand and loosen
the rigid coupling by loosening both screws.
Now carefully remove the shaft and put it aside.