00197973-10_SM_MaterialTower - 第46页
X Axis 0019797 3 - 10 / 02 , 2016 4-6 © ASM SIPLACE Mat. Tower S tor ag e Service Ma nual Step 2 Unplug bo th connection cables. Step 3 Loose n the screw of the coupl ing.

00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-5
4.1.4 Exchange steps
Step 1
Loosen the rigid coupling by loosening both
screws. Move the coupling up as far as possible
and refasten the upper screw. The couplin
g
should now be fixed on the shaft.
Securely hold the shaft in one hand and loosen
the rigid coupling by loosening both screws.
Now carefully remove the shaft and put it aside.

X Axis 00197973-10 / 02 , 2016
4-6 © ASM SIPLACE Mat. Tower Storage Service Manual
Step 2
Unplug both connection cables.
Step 3
Loosen the screw of the coupling.

00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-7
Step 4
Loosen all four screws holding the motor.
Carefully pull the motor out of the coupling and
put the new motor in its place.
Fasten all four screws holding the motor.
Step 5
Fasten the screw of the coupling using a torque
key adjusted on 7 Newton.