3-8 AIX-ML T-ID (C03) Tray Step Data Fig. C5-1 "T ray Step" Edit Window (C03_01) Magazine Alternate This alternate function can be activated between Magazine #1 and #2 in the same tray unit. When "Enable&q…

100%1 / 211
3-7
AIX-MLT-ID
(C02_02) Component ID
Set component IDs in the text boxes.
(C02_03) C
Set control commands in the text boxes.
Notice
If a control command other than the following ones is used, the step
becomes invalid.
- (hyphen) :
This command handles the steps as those for the
placement feeder location data.
E :
This command shows the end of the placement feeder
location data.
The step where "E" is set is valid.
S :
This command invalidates the steps specied as
placement feeder location data.
X :
This command invalidates the steps specied as
placement feeder location data and shows the end of the
data.
(C02_05) Component Library Comment
Displayed are the comments entered in the component library data.
(C02_06) Dir [deg], Carrier Type
Displayed is the data specied in the component library data.
(C02_07)
Used Parts
Displayed is the number of components to be used for one unit PCB.
0705-003
2.1 Description of Pattern Program
3-8
AIX-MLT-ID
(C03) Tray Step Data
Fig. C5-1 "Tray Step" Edit Window
(C03_01) Magazine Alternate
This alternate function can be activated between Magazine #1 and #2 in
the same tray unit.
When "Enable" is set in the "Magazine Alternate" text box, the machine
continues running with the magazine (spare one) automatically changed
and set ready for use right after the previously connected magazine gets
empty of the components required by the main machine.
Note
(a) It is not necessary to equally allocate the component allocation spots (step
and block Nos.). The need for the spare steps and blocks, etc., can be
determined freely for each individual magazines.
(b) The magazine alternate function is activated when a magazine gets empty of
the required types of components.
When components of the same type are set in several steps (stages), the
pallet alternate function is activated prior to this function.
(C03_02) Step Offset
Set the offset value for the component allocation to the multi-layer tray
feeder.
The set parameter is added to the step No. designated in the step data.
(C03_03) Magazine Step No.
The number of magazine steps can be set for Magazines #2 and #1.
(C03_04) Step
Shown are the step Nos. of the magazine.
The step Nos. have a button function. When one of these buttons is
pressed, the corresponding "Tray Step Information" window opens.
(C03_05) Block 1 through 9
Specify where in each step and block various components specied in
the tray data should be arranged.
0804-004
2.1 Description of Pattern Program
3-9
AIX-MLT-ID
2.1.2 Editing of Tray Step Information
When a step No. is selected in the "Tray Step" edit window (Fig. C5-1), the
"Tray Step Information" window appears, enabling the operator to edit the
tray step information.
[1] [2] [4][3] [5]
Fig. C6 "Tray Step Information [1-15 Step]" Window
[1] Block
Shown are the block Nos.
[2] Fdr. No.
Displayed are the Nos. of the feeders arranged in each block.
[3] Position Offset status
Select "R", "L", or "Free Position" as Reference Point X for the block.
Position offset X [mm], Y [mm]
Enter the reference coordinates of the tray viewed from the pallet
reference position of each block.
[4] C
The control commands can be selected.
[5] Component ID and Comment
Dis
play
ed are the component IDs entered in the "Tray" edit window and
the comments entered in the component library data.
0804-004