OM-1241-005_w - 第143页

4-16 AIX-ML T-ID 3.3 Inspection, Cleaning, and Lubrication Spots 0705-003 Upper Front Bearing Lower Front Bearing Upper Rear Bearing Lower Rear Bearing No. 18 Magazine Rail Y early Lubrication ( DAPHNE EPONEX GREASE No. …

100%1 / 211
4-15
AIX-MLT-ID
3.3 Inspection, Cleaning, and Lubrication Spots
0705-003
3.3.4 Magazine Base
A
B
VIEW A
VIEW B
Cylinder Connection Sections (4 places for each)
Every 3 Months Lubrication (MOLYNOC GREASE AP1)
Required Time: 10 minutes
Zero Magazine Base #2 (Upper) and open the exchange position door.
Turn off the power.
Wipe off old grease from the cylinder connection sections located on the bottom
side of the magazine base with an oiled rag.
Apply new grease with a syringe.
Move Magazine Base #1 (Lower) to the middle magazine change position and
continue the maintenance for Magazine Base #1 from the magazine #1 door.
Take ample care not to leave any waste threads after cleaning.
Note
Use No. 18 (green) nozzle.
No. 18
Notice
Fig. D9
4-16
AIX-MLT-ID
3.3 Inspection, Cleaning, and Lubrication Spots
0705-003
Upper Front Bearing
Lower Front Bearing
Upper Rear Bearing
Lower Rear Bearing
No. 18
Magazine Rail
Yearly Lubrication (
DAPHNE EPONEX GREASE No. 1
)
Required Time: 5 minutes
Draw out the magazine base.
Apply new grease to the bearings (8 pcs. on each rail) on the right and left magazine
rails (the front upper and lower rails and the rear upper and lower rails) with a
syringe.
Note
Use No. 18 (green) nozzle.
Fig. D10
4-17
AIX-MLT-ID
3.3 Inspection, Cleaning, and Lubrication Spots
0705-003
3.3.5 Magazine
Rack Shutter Fulcrum Section (6 places)
Every 3 Months Lubrication (MOLYNOC GREASE AP1)
Required Time: 30 minutes
Wipe off old grease from the upper and lower fulcrum sections of the rack shutter
with an oiled rag and apply new one to them with a syringe.
Take ample care not to leave any waste threads after cleaning.
Magnified View of Rack Shutter
Magnified View of Magazine Door
Note
No. 18
Use No. 18 (green) nozzle.
Notice