Printer 800 Services Required.pdf - 第6页
SERVICES REQU IRED MACHINE FOOTPRINT 3.6 Installatio n Manu al Chapter Issue 1 Jul 03

SERVICES REQUIRED
EXTERNAL SERVICES
3.4 Installation Manual Chapter Issue 1 Jul 03
Circuit Breakers The dc circuit breaker panel is located on the front of the M24 dc Power Supply
Module located at the rear of the machine and accessed through the rear panel.
The ac circuit breakers are located on the front of the M23 ac Power Supply
Module located at the rear of the machine and accessed through the rear panel.
Figure 3-3 Circuit Breaker Panels
dc Circuit Breaker Panel
ac Circuit Breaker Panel
M24 DC Power Module 155945
l
o
l
o
l
o
l
o
l
o
l
o
l
o
l
o
l
o
l
o
l
o
l
o
CB1
CB3 CB5 CB7 CB9 CB11
CB2 CB4 CB6 CB8 CB10 CB12
M23 AC POWER MODULE 155938
CB13 CB14 CB15 CB16 CB17
M23AC POWER MODULE 155938
CB13 CB14 CB15 CB16 CB17
CB15V 2.5A CB312V 1.2A CB524V10A CB724V US/
SW6A
CB924V
SW1.2A
CB1124V
SW12A
CB2-12V 1.2A
M24DC Power Module 155945
CB412V 2.5A CB624V 1.2A CB8 24V 2.5A CB1024V
SW10A
CB1212/24V
SW2.5A
M
U
L
T
I
M
O
V
E
S
/S
P
A
R
E
M
U
L
T
IM
O
V
E
X
1
3
/S
P
A
R
E
M
I
U
's
/S
Y
S
L
E
D
/S
P
A
R
E
S
E
N
S
O
R
/M
IU
F
I
N
E
P
I
T
C
H
A
U
T
O
F
L
E
X
S
T
E
P
P
E
R
M
T
R
S
/
H
E
A
D
L
IF
T
E
X
T
.E
S
T
O
P
S
/F
A
N
/
S
P
A
R
E
P.C
P
C
A
R
R
.B
R
A
K
E
/R
E
L
A
Y
S
C
O
N
T
A
C
T
O
R
S
/L
A
M
P
S
/S
P
A
R
E
S
P
A
R
E
P
R
E
S
S
.
A
M
P
/S
P
A
R
E
M
IU
's
/F
A
N
S
/C
A
M
L
I
G
H
T
'G
M
U
L
T
IM
O
V
E
X
1
2
2
/
X
1
2
l
o
l
o
l
o
l
o
l
o
l
o
l
o
l
o
l
o
l
o
l
o
l
o
View on Rear of Machine

SERVICES REQUIRED
MACHINE FOOTPRINT
Chapter Issue 1 Jul 03 Installation Manual 3.5
MACHINE FOOTPRINT
R
M
ax dim
ension
from
pivot point
470
CAUTION
OVER CURRENT PROTECTION.
Magnetic/thermal over current protectors
protect the machines internal wiring
and components from over heating/fire
during fault conditions. DEK require
additional machine supply protection
with the fitment of a wall mounted
circuit breaker rated to 16 amps and
conforming to national/federal
regulations.
Services required
Voltage:
100/110/120/200/210/220/230/240 V Single Phase
50/60Hz
Current:
110V - 16 Amps
120V - 15 Amps
200 - 220V - 8 Amps
230 - 240V - 7 Amps
Air Supply
Air to ISO 8573.1 standard quality class 2.3.3
Pressure 5 - 8 Bar at 5 Litre/min
Weight Boxed - TBD, Unboxed - TBD
Onboard Vacuum Unit (optional)
220 - 240V - 8 Amps
110 - 120V - 15 Amps
Single Phase 50/60Hz
Note
All dimensions in millimetres
Board transfer height 840 - 980 mm
Screen load height 925 - 1065 mm
Plan View
Front View
Side View (Right)
(1142 min to 1378 max)
1324
1106
104
(1651 min to 1791 max)
1771
(1351 min to 1491 max)
1471
1314
1757
Front of Board
606
(840 min to
980 max)
960
1150
362

SERVICES REQUIRED
MACHINE FOOTPRINT
3.6 Installation Manual Chapter Issue 1 Jul 03