00196429-0102 - AI Head Reconfiguration Kit SX12 C - 第62页

Installing the C&P20A Placement Head Installation and Removal of Options Option Nozzle Changer 62 Assembly Instructions / Mont ageanleitung Head Reconfiguratio n Kit C&P20A Installat ion and Re moval of Options 3…

100%1 / 64
Installing the C&P20A Placement Head
Connections on the Hotlink Card (Box PC) Assembly of the C&P20A Placement Head
Assembly Instructions / Montageanleitung Head Reconfiguration Kit C&P20A 61
Connecti ons on the Hotlink Card (B ox PC)
3.4.5 Connections on the Hotlink Card (Box PC)
Insert a USB stick or another appropriate storage medium into the USB slot of the station computer.
Save the machine data from the storage medium to the station computer.
Connections on the hotlink card
Legend
1. Hotlink connections CAM 0 to CAM 3 at the BOX PC.
2. CAM 2 - X2pr
03055214: stationary IC / FC camera 1
3. CAM 3 - X3pr
03055211: stationary IC / FC camera 2
Plug in the Hotlink cable for the relevant component
camera.
CAUTION
The Hotlink cables of the IC and FC cameras must be unplugged for the placement area in
which there is a C&P20A or a CPP head if no stationary camera is used here.
Do not connect the Hotlink cables which are not in use!
Do not confuse the Hotlink cables with the twisted pair cables!
Installing the C&P20A Placement Head
Installation and Removal of Options Option Nozzle Changer
62 Assembly Instructions / Montageanleitung Head Reconfiguration Kit C&P20A
Installation and Removal of Options
3.5 Installation and Removal of Options
Option Nozzle Changer
3.5.1 Option Nozzle Changer
When replacing the TwinHead by a C&P20A/CPP head the nozzle changer of the TwinHead must
be replaced by the appropriate nozzle changer for the C&P20A/CPP head.
For installing and removing the nozzle changer please refer to the Assemby Instruction "Nozzle
Changer SX1/2" [00196432-xx].
Option Verify Reject Bin
3.5.2 Option Verify Reject Bin
For installing and removing the option Verify component reject bin please refer to the Assembly In-
structions "Reject Bin SX1/2" [00196615-xx].
Final Work
3.6 Final Work
Switch the placement machine on at the main switch.
The head exchange will be indicated after the startup of the machine.
Confirm the new configuration.
Check the firmware version for the placement head and the HCU and perform a download, if needed.
Apply the data (zero point correction star and Z axis) from the placement head.
If the placement head is installed on a machine for the first time, it does not contain any calibration
data.
Calibrate the placement head.
If the placement head has already been used on another machine, you can use the calibration data
from the memory of the placement head.
Measure the nozzle changers and, if necessary, the stationary camera.
Perform the mapping procedure if necessary.
Perform another restart.
The conversion is completed with that.
CAUTION
Crash danger
Operate a placement head with its appropriate nozzle changer only. There is crash danger
when using a wrong nozzle changer.
NOTICE
If a second nozzle changer row is retrofitted, it may be necessary to loosen the COT insert and
move it outwards. Read the applicable service manual for this. After completion of work, this
needs to be fixed into place again and all attached parts (nozzle changer) must be remeasured.