Tg0249-PM-MM 0004-001 2-6

100%1 / 274
Tg0249-PM-MM
9910-001 2-5
2. Replacement Procedure of Vacuum Filter
Fig. 2.3
(3) Detach the vacuum filter from the cap.
Note: Do not throw away the cap.
(4) Attach a new vacuum filter to the cap.
(5) Engage the vacuum filter replacement jig with the hook of the cap and
push the cap straight into the placement head in the reverse order of cap
detachment.
Note: Push the cap into the placement head as far as possible.
(6) Follow the reverse procedure of the jig engagement (engagement proce-
dure for vacuum filter replacement jig) to slide it out horizontally from
the hook of the cap.
Tg0249-PM-MM
0004-001 2-6
Section 3
Special Selection Menus
9910-001 3-1 Tg0249-PM-MM