Tg0249-PM-MM (CURRENT DA T A) [SCREENS] Key Fig. 3.10-3 [SA VED/CURRENT] Key Saved Data  Fig. 3.10-4  9910-001 3-21 3. MANAGEMENT DA T A Display

100%1 / 274
Tg0249-PM-MM
3.2.1 Feeder Message Rate
Pick-up rates managed for each feeder (feeder slot No.) are displayed accord-
ing to the parameters specified at the “AUTO OPERATION SET-UP” display.
When the [FEEDER MESSAGE RATE] key is pressed at the “COMP. HAN-
DLING ERROR RATE DATA” display, the following display appears on the
screen.
When the [SAVED/CURRENT] key or the [SCREENS] key is pressed, an-
other display is selected.
Note: The -marked items are optional.
(SAVED DATA)
Fig. 3.10-1
Fig. 3.10-2
9910-001 3-20
3. MANAGEMENT DATA Display
[SAVED/CURRENT] Key
Current Data
[SCREENS] Key
Tg0249-PM-MM
(CURRENT DATA)
[SCREENS] Key
Fig. 3.10-3
[SAVED/CURRENT] Key
Saved Data
Fig. 3.10-4
9910-001 3-21
3. MANAGEMENT DATA Display
Tg0249-PM-MM
When one of the data keys is pressed, the feeder No. with the biggest param-
eter under the selected data key is displayed in the first line and feeder Nos.
having the subsequent (second, third, fourth, ...) biggest parameters follow.
When the [FDR. NO.] key is pressed, feeder Nos. are arranged in their ini-
tial order.
When the [CRG. SEL.] key is pressed, the display for the corresponding
feeder carriage appears on the screen.
Parameters set at the “AUTO OPERATION SET-UP (02/03)” display are
displayed after the label “MANAGEMENT DATA FDR. MESSAGE RATE”.
“Saved Data” : Shown are the parameters calculated just before the cur-
rent parameters.
“Current Data” : Shown are the parameters being calculated at present.
Examples in Figs. 3.10-1, 3.10-2, 3.10-3 and 3.10-4:
MANAGEMENT DATA FDR. MESSAGE RATE 10/100: Numerator 10 shows
the number of pick-up errors detected before 100 components are picked up.
Denominator 100 shows that 100 components are to be picked up. When 10
pick-up errors are detected, a message appears in the “MGT. INFO.” text box,
indicating that the pick-up rate has deteriorated. When the number of pick-up
errors does not reach “10” after 100 components are picked up, XX/XX is
reset to “00/00” and counting starts again.
The “FEEDER MESSAGE RATE (SAVED DATA)” shows the parameters
just before this delimiter.
When an alarm is issued, the blue feeder No. turns red at the “FEEDER
MESSAGE RATE (SAVED DATA)” display.
9910-001 3-22
3. MANAGEMENT DATA Display