Horizon UserManualV6 - 第118页

Parameter Definition Paste Dispense Speed This parameter sets the speed at which the paste dispenser moves across the screen thereby determining the amount of paste deposited on the screen. Minimum 10mm/sec Maximum 100mm…

100%1 / 378
Parameter Definition
Front Start Offset
(Vortex USC)
The distance, in from the front edge of the board, at which the cleaner is to finish.
Minimum -60mm
Maximum 60mm
Default 30mm
Increment 1mm
Rear Start Offset
(Blue USC)
This parameter determines the distance from the rear edge of the board that cleaning must
complete.
Minimum 0mm
Maximum 60mm
Increments 1mm
Rear Start Offset
(Vortex USC)
The distance, in from the rear edge of the board, at which the cleaner is to start.
Minimum -60mm
Maximum 60mm
Default 30mm
Increment 1mm
Vortex Cassette Life
(Vortex USC)
This parameter sets the number of cleaning strokes that are applied before a cleaning
cassette is replaced.
Minimum 0
Maximum 200
Default 20
Increment 1
Vortex Clean Rate
(Vortex USC)
This parameter sets the frequency (in print cycles) at which screen cleaning occurs.
Minimum 0
Maximum 200
Default 0
Increment 1
Vortex Solvent Rate
(Vortex USC)
This parameter sets the frequency (in cleaning cycles) at which solvent is dispensed.
Minimum 1
Maximum 10
Default 1
Increment 1
Vortex Vacuum Start
(Vortex USC)
The distance, in from the front edge of the board, where vacuum is applied.
Minimum Vacuum Stop
Maximum Board Width
Default 0mm
Increment 1mm
Vortex Vacuum Stop
(Vortex USC)
The distance, in from the front edge of the board, where vacuum application is stopped.
Minimum -100mm
Maximum Vacuum Stop
Default 0mm
Increment 1mm
Vortex Vacuum Rate
(Vortex USC)
This parameter sets the frequency (in cleaning cycles) at which vacuum is applied.
Minimum 1
Maximum 10
Default 1
Increment 1
Vortex Vacuum Period
(Vortex USC)
This parameter sets the period for which vacuum is applied.
Minimum 1 sec
Maximum 10 secs
Default 5 secs
Increment 1 sec
Paste Dispense Rate This parameter sets the number of print cycles which occur between cycling of the paste
dispense system.
Minimum 0 (Dispenser switched off)
Maximum 100
Increment 1
Software Version 6 User Manual 1.101
MACHINE PROGRAMMING
MENU PARAMETERS
Parameter Definition
Paste Dispense Speed This parameter sets the speed at which the paste dispenser moves across the screen
thereby determining the amount of paste deposited on the screen.
Minimum 10mm/sec
Maximum 100mm/sec
Increment 1mm/sec
Paste Start This parameter determines start position of the paste dispense measured from the centre
line of the machine. The limits depend on the type of screen fitted.
Minimum
No adapter -255mm
255 -230mm
Sanyo -210mm
Heraeus -172mm
249 -215mm
Default -half the board length
Maximum
No adapter +255mm
255 +230mm
Sanyo +210mm
Heraeus +172mm
249 +215mm
Default +half the board length
Paste stop This parameter determines the stop position of the paste dispense measured from the
centre line of the machine. The maximum value depends on the type of screen fitted.
Minimum
No adapter -255mm
255 -230mm
Sanyo -210mm
Heraeus -172mm
249 -215mm
Default -half the board length
Maximum
No adapter +255mm
255 +230mm
Sanyo +210mm
Heraeus +172mm
249 +215mm
Default +half the board length
Knead Boards This parameter sets the number of boards to be printed using the knead sequence.
Minimum 1
Maximum 10
Increment 1
Knead Deposits This parameter sets the number of print strokes to be carried out on each of the kneaded
boards.
Minimum 2
Maximum 20
Increment 1
Paste Knead Period This parameter sets the time period between print cycles which, if exceeded, initiates a
paste knead sequence.
Minimum 0 (paste kneading switched off)
Maximum 30 minutes
Increment 1 minute
Knead After Dispense If this option is enabled and a paste dispense has been performed (either Manual or
Automatic) a paste knead is performed (as defined by the paste knead parameters in the
board file) on the next board immediately following the paste dispense.
ENABLED; DISABLED
Paste While Clean This parameter enables the machine to carry out a paste dispense while cleaning the
screen. Available modes are:
DISABLED, MODE 1, MODE 2, BOTH MODES
1.102 User Manual Software Version 6
MACHINE PROGRAMMING
MENU PARAMETERS
Parameter Definition
Alternate Disp This parameter gives the option to dispense at either ENDS or CENTRE. ENDS
dispenses at the outer 25% of the squeegees. CENTRE dispenses along an area of 25%
either side of the centre line.
ENDS; CENTRE
Alternate Disp Rate This parameter enables the user to select the ratio of alternate dispenses to standard
dispenses.
No alternate dispense
Every dispense
Every second dispense etc.
Paste With Board This parameter gives the option to dispense paste with a board loaded and held at print
height. This prevents paste dropping through the image on the screen. Options are:
ENABLED; DISABLED
NOTE
With enabled selected the parameter Paste While Clean is removed.
Board Count This function provides the facility for the print cycle to be halted automatically on a
board count basis. If the board stop count is zero this function is not active. When a
print run is started, a count is made from the STOP CYCLE AFTER value to zero
decrementing by one for each board printed. When the counter reaches zero, the print
cycle is finished and control returned to the main display page and the beacon is set to
amber, thus indicating that the machine requires operator attention. The operator has
access to all of the machines options. Once the operator has performed any required
operations, the run button can be pressed to continue the print cycle.
Minimum 0 Boards
Maximum 500 Boards
Increments 1 Board
Stop After Idle This parameter when enabled sets the time the product is held in contact with the screen
until both upline and downline systems are ready to transfer.
Minimum 0 mins.
Maximum 200 mins.
Increments 1 min.
Screen X Forward Nominal position of the X front screen actuator which ensures that corresponding screen
and board fiducials can be viewed from a single camera position.
Minimum -20mm
Maximum +20mm
Increment 0.004mm
Screen X Rear Nominal position of the X rear screen actuator which ensures that corresponding screen
and board fiducials can be viewed from a single camera position.
Minimum -20mm
Maximum +20mm
Increment 0.004mm
Screen Y Axis Nominal position of the Y screen actuator which ensures that corresponding screen and
board fiducials can be viewed from a single camera position.
Minimum -10mm
Maximum +10mm
Increment 0.004mm
SPC Configuration This preference allows the user to set up the Machines SPC operation. On selecting the
SPC Configuration by pressing the Incr. or Decr. buttons, a window opens and the menu
bar changes.
See the SPC Configuration section later in this chapter for further details.
Image Detail This parameter allows the user to modify the screen image data of the selected screen
library file. Once selected, pressing Incr. or Decr. Keys opens the Image Detail
Configuration page.
NOTE
This parameter is only displayed, if Screen Size in Set Preferences has been selected to
Screen Library.
Software Version 6 User Manual 1.103
MACHINE PROGRAMMING
MENU PARAMETERS