Horizon UserManualV6 - 第179页

Error Message Interpretation System Suspended While Covers Open This error reports that whilst the machine was switched on, one or more of the cover interlock switches were out of position. Table Movement Inhibited, Came…

100%1 / 378
Error Message Interpretation
Rail Lifted Error, Check
Tooling
This error reports that either the left rail lifted sensor or the
right rail lifted sensor are out of their home positions when
any of the following moves are taking place:
Alignment of the screen
Board stop moving into position
Initialization of the machine
Initialization of the AutoFlex tooling
Possible causes are:
A misfed board
Tooling/object on the rising table striking the underside of
the rails
Rear Squeegee Error This error reports that the rear squeegee failed to reach its
fully up position.
Rear Squeegee Pressure
Error
When this error is detected a new window displays the set
pressure reading and the actual pressure reading.
Rising Table Error This error reports that the rising table has either failed to
reach its fully down position or that when attempting to
reach the required height during the machine cycle did not
achieve the positional accuracy.
Rising Table Out of
Position
This error reports that either; the camera axes are not at the
home position when the rising table is to be lifted, or the
rising table is at a height greater than vision height by 1mm.
Screen Cleaner Out Of
Position
This error reports that the screen cleaner is out of position.
Possible causes are:
Screen Cleaner not at the home position.
Home sensor - enter Diagnostics, Digital Inputs and check
the sensor changes state.
If a screen cleaner is not fitted, check that the home sensor
is not connected.
Screen Couplings Not
Extended
This error reports that the screen couplings have failed to
extend within the 4 second time-out period.
Screen Fiducial Not Found This error reports that the vision system has been unable to
locate the screen fiducial.
Screen XF Error This error reports that the X forward screen actuator failed
to initialize to its central datum.
Screen XR Error This error reports that the X rear screen actuator failed to
initialize to its central datum.
Screen Y Error This error reports that the Y screen actuator failed to
initialize to its central datum.
Set Pressure %2.21f Actual
Pressure %2.21f
(Front/Rear Squeegee)
This error reports if the front/rear squeegee pressure differs
from the pressure set by more than ± 1.00Kg.
Stop After Idle Time
Exceeded
This error reports if the idle time is exceeded, the options to
continue or abort are displayed. Continue resets the idle
timer or abort allows for Manual or Auto unload.
System Power Down This error reports that the 24V motor power has been
switched off either by the Emergency Stop button being
activated (including upline and downline external
machines) or that the removable frame access cover has
been removed
4.6 User Manual Software Version 6
ERROR MESSAGES
ERROR MESSAGE LISTING
Error Message Interpretation
System Suspended While
Covers Open
This error reports that whilst the machine was switched on,
one or more of the cover interlock switches were out of
position.
Table Movement Inhibited,
Camera Not Home.
This error reports that the camera is over the table and the
mint is sent an instruction to move the rising table.
This Diagnostic Cannot
Run Until Proflow Is At
home
This error reports if proflow is not in the home position
(Print Carriage Diagnostics only).
This Diagnostic Cannot
Run With Proflow Fitted
This error reports if in Print Carriage Diagnostics, Move
Print Carriage to Paste Position is selected.
Unable to Find Fiducial This error reports that the vision system is unable to locate
the relevant screen or board fiducial.
Upline Board Transfer
Error
This indicates that there is a problem in loading a board
from the upline machine.
Upline Machine Not
Available
This error reports that the upline machine is unavailable to
accept the next board.
Window Error This error reports that the menu structure has failed to open
correctly.
X Actuator Limit Exceeded This error reports that either X actuators are driven past its
limit set during calibration.
Y Actuator Limit Exceeded This error reports that either Y actuators are driven past its
limit set during calibration.
Software Version 6 User Manual 4.7
ERROR MESSAGES
ERROR MESSAGE LISTING
4.8 User Manual Software Version 6
ERROR MESSAGES
ERROR MESSAGE LISTING