Horizon UserManualV6 - 第207页

SCREEN CHANGE Selecting this diagnostics module opens the following window: The menu bar changes to the following: Run Diagnost Next Previous Exit Next / Previous keys have no function in this application. Run Diagnost a…

100%1 / 378
Drive X Rear Motor
Using Jog Buttons
Selecting this diagnostic function drives the X rear actuator using the jog
buttons. The right jog button drives the X rear actuator right at slow speed and
the left jog button drives it left, stopping immediately the button is released.
Drive Y Motor
Using Jog Buttons
Selecting this diagnostic function drives the Y actuator using the jog buttons.
The right jog button drives the Y actuator forward at slow speed and the left jog
button drives it to the rear, stopping immediately the button is released.
Toggle Chase
Clamp
Selecting this diagnostic function alternately energizes and de-energizes the
chase clamp solenoid, displaying On when the clamps are energized and Off
when the clamps are de-energized.
Cycle Alignment
System
Selecting this diagnostic function starts a continuous cycle of driving the screen
actuators to each of the positions in the table below in sequence, dwelling for 2
seconds at each point and continuing the cycle.
The positions are given as XF, XR and Y in mm from the home position and are
as follows:
1
0, 0, 0.
2
+20, +10, +10.
3
0, 0, 0.
4
-20, -10, -10.
5
0, 0, 0.
6
+10, +20, -10.
7
0, 0, 0.
8
-10, -20, +10.
If data logging is enabled, every time the screen returns to 0,0,0, locate a screen
fiducial and its coordinates are appended to D:\Program
Files\DEK\Machinecontrol\Printer\Screen.Dat file. This continuous cycling is
terminated by selecting the stop key or when the set cycle count has been
reached.
Cycle Count This diagnostic function displays the amount of cycles done and the amount of
cycles to go to complete the cycle count.
5.24 User Manual Software Version 6
DIAGNOSTICS
SCREEN ALIGNMENT
SCREEN CHANGE Selecting this diagnostics module opens the following window:
The menu bar changes to the following:
Run
Diagnost
Next Previous Exit
Next / Previous keys have no function in this application.
Run Diagnost activates the toggle screen clamps diagnostic function.
Exit returns operation to the module diagnostics page.
Toggle Screen
Clamps
Selecting this diagnostic function alternately energizes and de-energizes the
screen clamps, displaying On when energized and Off when de-energized.
Screen Sensor This diagnostic function continuously displays the status of the screen sensor.
Software Version 6 User Manual 5.25
DIAGNOSTICS
SCREEN CHANGE
Screen C
h
ange D
i
agnost
i
cs
OFF
Screen Sensor
ON
Toggle Screen Clamps
SCREEN CLEANER
Selecting this diagnostics module opens the following window:
NOTE
Toggle Paper Feed and Cleaner Paper Low/Advance are not present when the
Vortex under screen cleaner is fitted.
The menu bar changes to the following:
Run
Diagnost
Adjust Next Previous Exit
Next / Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight bar.
Exit returns operation to the module diagnostics page.
Adjust opens the following window:
The menu bar changes to the following:
Incr. Decr. Exit
Incr. / Decr. keys change the value of the cycle count.
Exit returns operation to the screen cleaner diagnostics page.
Toggle Dry Wipe
Blade
Selecting this diagnostic function raises and lowers the cleaner body assembly,
displaying On when the cleaner body assembly is raised and Off when the
cleaner body assembly is lowered.
5.26 User Manual Software Version 6
DIAGNOSTICS
SCREEN CLEANER
Screen C
l
eaner D
i
agnost
i
cs
..more
ON
ON
ON
ON
ON
ON
ON
ON
ON
Cleaner Paper Low/Advance
Cleaner Solvent Low
Pinch Valve Fitted
Toggle Dry Wipe Blade
Toggle Pinch Valve (if fitted)
Toggle Paper Feed
Toggle Vacuum
Toggle Solvent Feed/Tank Press
Toggle Screen Cleaner Home Clamp
Cycle Pinch Valve
Cycle Clean Blade
Cycle Count
Done :-
0, To go :-
50
Cleaner Cycle Parameters
CYCLE COUNT
50.0
Cycles