Horizon UserManualV6 - 第296页

Parameter Definition Screen Oblique This parameter sets the level of screen oblique light. Minimum - 0 Maximum - 15 Increments - 1 Default - 8 This parameter is for the green camera only. Board Oblique This parameter set…

100%1 / 378
Parameter Definition
Board Graphic This parameter sets the colour of the graphic box drawn around the board
site. The options are:
Black
White
Default - White
This parameter has no function on the Horizon and Infinity machines.
Board Graphic X The position of the inspection window. This parameter is used to finely
adjust the inspection window in the X direction, any adjustment made
affects the site X coord parameter.
Minimum - -3.5mm
Maximum - 3.5mm
Increments - 0.01mm
Default - 0mm
Board Graphic Y The position of the inspection window. This parameter is used to finely
adjust the inspection window in the Y direction, any adjustment made
affects the site Y coord parameter.
Minimum - -3.5mm
Maximum - 3.5mm
Increments - 0.01mm
Default - 0mm
Window Left This parameter sets the position of the window relative to the centre of
the image.
The Minimum and Maximum values are calculated from the vision
calibration and vary from machine to machine.
Increments - 0.1mm
Default - -1.5mm
Window Top This parameter sets the position of the window relative to the centre of
the image.
The Minimum and Maximum values are calculated from the vision
calibration and vary from machine to machine.
Increments - 0.1mm
Default - -1.5mm
Window Width This parameter sets the width of the inspection window.
The Minimum and Maximum values are calculated from the vision
calibration and vary from machine to machine.
Increments - 0.1mm
Default - 3mm
Window Height This parameter sets the height of the inspection window.
The Minimum and Maximum values are calculated from the vision
calibration and vary from machine to machine.
Increments - 0.1mm
Default - 3mm
Screen Vertical This parameter sets the level of screen vertical light.
Minimum - 0
Maximum - 15
Increments - 1
Default - 8
Board Vertical This parameter sets the level of board vertical light.
Minimum - 0
Maximum - 15
Increments - 1
Default - 8
Software Version 6 User Manual 8.45
2Di INSPECTION
MENU PARAMETERS
Parameter Definition
Screen Oblique This parameter sets the level of screen oblique light.
Minimum - 0
Maximum - 15
Increments - 1
Default - 8
This parameter is for the green camera only.
Board Oblique This parameter sets the level of board oblique light.
Minimum - 0
Maximum - 15
Increments - 1
Default - 8
This parameter is for the green camera only.
Screen Inner LR This parameter sets the level of screen inner left/right light.
Minimum - 0
Maximum - 15
Increments - 1
Default - 8
This parameter is for the silver camera only.
Screen Inner FR This parameter sets the level of screen inner front/rear light.
Minimum - 0
Maximum - 15
Increments - 1
Default - 8
This parameter is for the silver camera only.
Screen Outer LR This parameter sets the level of screen outer left/right light.
Minimum - 0
Maximum - 15
Increments - 1
Default - 8
This parameter is for the silver camera only.
Screen Outer FR This parameter sets the level of screen outer front/rear light.
Minimum - 0
Maximum - 15
Increments - 1
Default - 8
This parameter is for the silver camera only.
Board Inner LR This parameter sets the level of board inner left/right light.
Minimum - 0
Maximum - 15
Increments - 1
Default - 8
This parameter is for the silver camera only.
Board Inner FR This parameter sets the level of board inner front/rear light.
Minimum - 0
Maximum - 15
Increments - 1
Default - 8
This parameter is for the silver camera only.
Board Outer LR This parameter sets the level of board outer left/right light.
Minimum - 0
Maximum - 15
Increments - 1
Default - 8
This parameter is for the silver camera only.
8.46 User Manual Software Version 6
2Di INSPECTION
MENU PARAMETERS
Parameter Definition
Board Outer FR This parameter sets the level of board outer front/rear light.
Minimum - 0
Maximum - 15
Increments - 1
Default - 8
This parameter is for the silver camera only.
Limit Set Options This parameter enables the output of these inspections.
Blockage
Smear
Paste
Alignment
Bridging
Volume
Software Version 6 User Manual 8.47
2Di INSPECTION
MENU PARAMETERS