StackShotManual_1_5.pdf - 第22页

 22     Figure  8 ‐ Automatic  Distance  Mode   Note:  If  you  press  the  FWD  or  BACK  buttons  after  th e  stack  has  completed,  the  rail  will  move  in  the  direction  desire…

100%1 / 50
21
PresstheUPorDOWNbuttontoinitiatethesequence.Themotorwillmovebacktothestart
positionandbegincapturingpictures.Thestatus li newillindicatewhichstepisinprogress:
Mode: Auto-Dist
Dist/Step: 200 um
Running: 3/10
Ifyoupressanybuttonduringthistimeitwillstopthemotor,abortthesequence,andthe
displaywillshowAbortedandgiveyoutheoptiontorunthesequenceagain.Torestartthe
sequence,presseithertheUPorDOWNbutton.
Mode: Auto-Dist
Dist/Step: 200 um
> Aborted. Run Again?
Change Settings
Whenthesequencecompletes,youalso havetheoptiontorestartbypressingtheUPorDOWN
button.Ifyouwanttochoosenewstartandendpositions,presstheSELECTbuttonsothatthe
cursorisnexttoChangeSettings”.PresstheUPorDOWNbutton.Youcanthenchooseanew
startandendposition.SeeFigure8belowtode monstrate“AutoDistance”mode.
22
Figure8‐AutomaticDistanceMode
Note:IfyoupresstheFWDorBACKbuttonsafterthestackhascompleted,therailwillmovein
thedirectiondesired.IfyouthenchooseRunAgain?fromthemenu, itwillusethecurrent
positionoftherailasthestartratherthantheoriginalposition.Thisallowsadjustmentstothe
startingpointwithouthavingtogothroughandchooseanewstartandendpointforthestack.

23
3.9 Mode:ManualDistance
3.9.1 Overview
ManualDistancemode(“ManualDist”)isidenticalto“AutomaticDistance”mode(seesection
3.8above)exceptthateachstepmustbemanuallyadvanced.Thisisusefulforapplications
wherethecamera,subject,dye,ormaterialmayhaveavariableamountoftimebeforethe
nextpictureisdesired.Thismodeisgearedtoward specializedapplicationsandwewould
recommendtheuseof“AutomaticDistance”undermostcircumstances.
3.9.2 Advancingtherail
Afterthestartandstoppointshavebeenselectedlikeinthe“AutomaticDistance”mode,the
railwillautomaticallymovetothestartpointandtakethefirstpicture(orpictures).Oncethe
“Toff”timeexpiresyouwillseethefollowing:
Mode: ManualDist
Dist/Step: 200 um
> Up/Down for next
AtthispointyoumaypressUPorDOWNtoadvancetothenextposition.
