M2series_ServiceManual_e.pdf - 第33页

3 Mechanical Section 3-1 3 Mechanical Section

100%1 / 92
2 Periodical Checks
2-6
Fixed Camera
Clean half mirror and lens (lens filter).
)
”Camera” in 3 Mechanical Section.
Teach Camera
Clean lens.
)
”Camera” in 3 Mechanical Section.
Scan Camera
Clean lens.
Clean mirror in front of camera.
)
”Camera” in 3 Mechanical Section.
Camera Illumination
Check movement and brightness.
Operation Switches
Check if all actuators work properly in the Signal I/O screen.
Check emergency stop switch.
Alarm Beacon
Check if all lamps light.
Make sure it is fixed securely.
Hazard Alarm
Check if alarm sounds.
Warning Alarm
Check if alarm sounds.
Cameras
Execute “VISION TEST” and check result.
Pickup Coordinates
Check feeder banks.
Electrodes on Feeder Bank
Check the condition.
)
”Electrodes on Feeder / Feeder Bank” in 4 Electrical Section.
Placement
Make sure components are placed on specified places.
3 Mechanical Section
3-1
3
Mechanical Section
3 Mechanical Section
3-2
Head Cover Unit
Removing/Installing the Head Cover Unit
To carry out maintenance of the head unit, the cover unit on the front of the head must be removed. The
removal/installation procedure for the head cover unit is given below.
NOTE: Before removing the head cover unit, the main power to the machine must be turned OFF and protective
gloves must be worn for safety reasons.
ACTION: Removal
Pull up the under-side of the upper resin cover to remove it from the cover clamp. (The upper-side of the
cover can be left fixed.)
Unscrew the four plastic screws by hand.
Upper (two screws)